|
|
||||||||
Guest Access | Sign In via User Name/Password |
|||||||||
Chest, Vol 85, 232-235, Copyright © 1984 by American College of Chest Physicians
ARTICLES |
RH Poe, MC Kallay, CM Wicks and CL Odoroff
We prospectively studied results of 103 consecutive transthoracic needle biopsies of lung lesions suspicious for malignancy to determine if lesion size, depth within the lung, hyperinflation, second needle passes, or 100 percent oxygen breathing influenced the incidence of pneumothorax. Thirty-eight patients (37 percent) developed pneumothorax. Ten (10 percent) required tube thoracostomy for re- expansion. Five of the ten requiring the chest tube had clinically severe obstructive lung disease. In all patients, greater depth (D) in centimeters of needle penetration significantly increased the probability (p) of pneumothorax (p much less than .001) and can be estimated by the equation: (formula see text) The estimated probability of pneumothorax is 13 percent at 1 cm, 49 percent at 4 cm, and 86 percent at 7 cm. An increase in total lung capacity above predicted added additional risk of pneumothorax (p less than .02). Oxygen breathing did not significantly reduce the incidence of pneumothorax, but may reduce size by increasing the rate of reabsorption. The other factors had little influence. We conclude that the more central location of the lesion and pre-existing lung hyperinflation determine the risk of pneumothorax.
This article has been cited by other articles:
![]() |
C. M. Heyer, T. Kagel, S. P. Lemburg, J. W. Walter, J. de Zeeuw, K. Junker, K.-M. Mueller, V. Nicolas, and T. T. Bauer Transbronchial Biopsy Guided by Low-Dose MDCT: A New Approach for Assessment of Solitary Pulmonary Nodules Am. J. Roentgenol., October 1, 2006; 187(4): 933 - 939. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Gupta, S. Krishnamurthy, L. D. Broemeling, F. A. Morello Jr, M. J. Wallace, K. Ahrar, D. C. Madoff, R. Murthy, and M. E. Hicks Small (<=2-cm) Subpleural Pulmonary Lesions: Short- versus Long-Needle-Path CT-guided Biopsy--Comparison of Diagnostic Yields and Complications Radiology, February 1, 2005; 234(2): 631 - 637. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. R. Geraghty, S. T. Kee, G. McFarlane, M. K. Razavi, D. Y. Sze, and M. D. Dake CT-guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax Rate Radiology, November 1, 2003; 229(2): 475 - 481. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Manhire, M Charig, C Clelland, F Gleeson, R Miller, H Moss, K Pointon, C Richardson, and E Sawicka Guidelines for radiologically guided lung biopsy Thorax, November 1, 2003; 58(11): 920 - 936. [Full Text] [PDF] |
||||
![]() |
E. vanSonnenberg, B. W. Goodacre, G. R. Wittich, R. Logrono, P. T. Kennedy, and J. B. Zwischenberger Image-guided 25-gauge Needle Biopsy for Thoracic Lesions: Diagnostic Feasibility and Safety Radiology, May 1, 2003; 227(2): 414 - 418. [Abstract] [Full Text] [PDF] |
||||
![]() |
M Henry, T Arnold, and J Harvey BTS guidelines for the management of spontaneous pneumothorax Thorax, May 1, 2003; 58(90002): ii39 - 52. [Full Text] |
||||
![]() |
M. J. Wallace, S. Krishnamurthy, L. D. Broemeling, S. Gupta, K. Ahrar, F. A. Morello Jr, and M. E. Hicks CT-guided Percutaneous Fine-Needle Aspiration Biopsy of Small (<=1-cm) Pulmonary Lesions Radiology, December 1, 2002; 225(3): 823 - 828. [Abstract] [Full Text] [PDF] |
||||
![]() |
C M Richardson, K S Pointon, A R Manhire, and J T Macfarlane Percutaneous lung biopsies: a survey of UK practice based on 5444 biopsies Br. J. Radiol., September 1, 2002; 75(897): 731 - 735. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Saji, H. Nakamura, T. Tsuchida, M. Tsuboi, N. Kawate, C. Konaka, and H. Kato The Incidence and the Risk of Pneumothorax and Chest Tube Placement After Percutaneous CT-Guided Lung Biopsy* : The Angle of the Needle Trajectory Is a Novel Predictor Chest, May 1, 2002; 121(5): 1521 - 1526. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. B. Haramati and G. Aviram What Constitutes Effective Management of Pneumothorax After CT-Guided Needle Biopsy of the Lung? Chest, April 1, 2002; 121(4): 1013 - 1015. [Full Text] [PDF] |
||||
![]() |
P. W. Wong, T. Stefanec, K. Brown, and D. A. White Role of Fine-Needle Aspirates of Focal Lung Lesions in Patients With Hematologic Malignancies Chest, February 1, 2002; 121(2): 527 - 532. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. K. Lang, R. Ghavami, V. C. Schreiner, S. Archibald, and J. Ramirez Autologous Blood Clot Seal to Prevent Pneumothorax at CT-guided Lung Biopsy Radiology, July 1, 2000; 216(1): 93 - 96. [Abstract] [Full Text] |
||||
![]() |
H. Tsukada, T. Satou, A. Iwashima, and T. Souma Diagnostic Accuracy of CT-Guided Automated Needle Biopsy of Lung Nodules Am. J. Roentgenol., July 1, 2000; 175(1): 239 - 243. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Cox, C. Chiles, C. M. McManus, S. L. Aquino, and R. H. Choplin Transthoracic Needle Aspiration Biopsy: Variables That Affect Risk of Pneumothorax Radiology, July 1, 1999; 212(1): 165 - 168. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |