Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by LoCicero, J.
Right arrow Articles by Michaelis, L. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LoCicero, J., 3d
Right arrow Articles by Michaelis, L. L.

Chest, Vol 87, 820-822, Copyright © 1985 by American College of Chest Physicians


ARTICLES

Experimental air leaks in lung sealed by low-energy carbon dioxide laser irradiation

J LoCicero 3d, JW Frederiksen, RS Hartz, MW Kaufman and LL Michaelis

When a focused carbon dioxide laser beam strikes a surface of tissue, the light energy is converted instantly into thermal energy, causing cells directly in the laser's path to vaporize. Because the carbon dioxide laser's energy is well absorbed by water, this thermal effect is attenuated at a distance of 100 mu. If the laser beam is "defocused," the same thermal energy is dissipated over a larger area, causing only desiccation and melting of tissue without vaporization; however, the depth of injury remains shallow. This modified technique has been used to seal artificially created air leaks in the canine lung. Twelve mongrel dogs were anesthetized, intubated, and ventilated. The lingula was exposed sterilely through a left thoracotomy. A 1 X 3- mm hole was made in the lung at 1 cm from the edge. The created air and blood leaks were sealed with a defocused carbon dioxide laser beam set at 8 W (32 W/sq cm). Each tissue "weld" withstood 40 cm H2O of peak ventilation pressure without leak. At the time of reoperation three weeks later, there was apparent complete healing of the pulmonary surface. No air leaks were present. Histologic examination showed a small zone of amorphous coagulated pleura and lung overlying a zone of minimal atelectasis. Normal lung was present within 150 mu of the laser seal. This new technique was performed safely and easily with currently available carbon dioxide lasers in the laboratory. It is presently undergoing intraoperative trials in a controlled clinical setting.


This article has been cited by other articles:


Home page
ChestHome page
N. Sawabata, M. Ikeda, A. Matsumura, H. Maeda, S. Miyoshi, and H. Matsuda
New Electroablation Technique Following the First-Line Stapling Method for Thoracoscopic Treatment of Primary Spontaneous Pneumothorax
Chest, January 1, 2002; 121(1): 251 - 255.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American College of Chest Physicians.