Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marini, J.
Right arrow Articles by Lamb, V
Right arrow Search for Related Content
PubMed
Right arrow Articles by Marini, J.
Right arrow Articles by Lamb, V

Chest, Vol 89, 56-63, Copyright © 1986 by American College of Chest Physicians


ARTICLES

Bedside estimation of the inspiratory work of breathing during mechanical ventilation

JJ Marini, RM Rodriguez and V Lamb

The work of chest inflation, WI, is a primary determinant of the need for ventilatory support and an integrative index of elastic and resistive impedance. Although the mechanical work performed by a ventilator in moving gas into the passive chest (WI = integral of PV dt) can be determined by measuring the area enclosed by a display of airway pressure (P) against delivered volume (V), the instrumentation required is not routinely available at the bedside. Under conditions of constant flow, however, inspiratory time represents an analog of delivered volume, and airway pressure can be recorded easily by equipment normally employed to monitor pulmonary vascular pressures. We reasoned that the area beneath the airway pressure vs time tracing should accurately reflect WI for unassisted breaths delivered by the ventilator at constant flow. We computed estimates of WI from simultaneous pressure-volume (PV) and pressure-time (PT) plots during square-wave inflation in 20 acutely ill patients. Ventilator settings were varied over the usual clinical range for tidal volume (10 to 15 ml/kg) and inspiratory flow (40 to 80 L/min). PV and PT estimates agreed closely; across the four setting combinations tested, the difference between PV and PT estimates averaged 2.4 +/- 5.6 percent (means +/- SD, r = 0.99). Furthermore, the reproducible geometric configuration of the curves generated allowed accurate estimation of WI from routine beside observations of tidal volume and peak dynamic and static inflation pressures, without the need for specialized equipment or area measurement. Such simplified estimates could serve in clinical practice to gauge the ventilatory workload and to monitor changes in respiratory impedance.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American College of Chest Physicians.