Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Banner, M.
Right arrow Articles by Desautels, D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Banner, M.
Right arrow Articles by Desautels, D.

Chest, Vol 90, 212-217, Copyright © 1986 by American College of Chest Physicians


ARTICLES

Flow resistance of expiratory positive-pressure valve systems

MJ Banner, S Lampotang, PG Boysen, TE Hurd and DA Desautels

The flow-resistive characteristics of a variety of commercially available expiratory positive-pressure valve systems used to provide continuous positive airway pressure (CPAP) and positive end-expiratory pressure were evaluated. One flow-resistor and seven threshold-resistor expiratory pressure valve systems were set at 5, 10, 15, 20, and 25 cm H2O of expiratory pressure, and sinusoidal exhaled flows peaking at 50,100, and 200 L/min were directed through each valve at each level of expiratory pressure. The Siemens flow-resistor valve demonstrated the greatest deviation in pressure above set CPAP levels at peak flow rates of 100 and 200 L/min, which suggests high resistance to exhaled flow. The Vital Signs threshold-resistor valve demonstrated the least deviation in pressure from set CPAP levels at all rates of exhaled flow, which suggests low flow resistance. The Emerson and IMV Bird threshold-resistor systems resisted flow less than the BEAR-2 and the Puritan-Bennett MA-2 and 7200 inflatable-balloon threshold-resistor- like valve systems. These data suggest that threshold resistors may be classified as low-resistance or high-resistance types. Using only low- resistance threshold resistors for CPAP may minimize the incidence of barotrauma and other deleterious effects related to airway pressure.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American College of Chest Physicians.