Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Light, R.
Right arrow Articles by Kryger, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Light, R.
Right arrow Articles by Kryger, M.

Chest, Vol 91, 444-449, Copyright © 1987 by American College of Chest Physicians


ARTICLES

Perfluorochemical artificial blood as a volume expander in hypoxemic respiratory failure in dogs

RB Light, R Perez-Padilla and MH Kryger

The perfluorochemical O2-transport fluid, Fluosol-DA 20 percent (PFC), is being clinically evaluated as a volume expander in patients who are unable to receive blood products. Since patients treated with Fluosol- DA may be at risk of developing adult respiratory distress syndrome (ARDS) as a complication of the original disorder for which they were transfused, we examined central hemodynamics and gas exchange in anesthetized O2-ventilated dogs with oleic-acid induced pulmonary edema before and after transfusion with 400 ml of either PFC (n = 5) or whole blood (n = 5). Transfusion produced similar increases in cardiac output, pulmonary and systemic vascular pressures and intrapulmonary shunt in the two groups. Arterial O2 tension, however, fell from 209 +/- 117 to 172 +/- 81 mmHg in the blood transfused group but increased from 219 +/- 145 to 302 +/- 138 mmHg in the PFC group. Arterial O2 content, on the other hand, increased in the blood transfused group due to an increase in hematocrit, but fell with PFC because of hemodilution. This lower total arterial O2 content in the PFC group was, however, compensated for by more efficient O2 transport by the PFC in that the PFC arteriovenous O2 content difference accounted for 26 percent of the total arteriovenous O2 content difference, making it about four times as efficient as hemoglobin in tissue O2 delivery. Fluosol DA, 20 percent, is an effective volume expander in this model of hypoxemic respiratory failure, and it can transport significant amounts of O2 even in the presence of a substantial intrapulmonary shunt.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American College of Chest Physicians.