Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McKelvie, R.
Right arrow Articles by Jones, N.
Right arrow Search for Related Content
PubMed
Right arrow Articles by McKelvie, R.
Right arrow Articles by Jones, N.

Chest, Vol 92, 777-782, Copyright © 1987 by American College of Chest Physicians


ARTICLES

Measurement of cardiac output by CO2 rebreathing in unsteady state exercise

RS McKelvie, GJ Heigenhauser and NL Jones
Ambrose Cardiorespiratory Unit, McMaster University Health Sciences Centre, Hamilton, Ontario, Canada.

The ability to determine cardiac output (Q) noninvasively during a nonsteady state (NSS) incremental exercise test was assessed. Seven healthy subjects performed two maximal incremental cycle ergometer exercise tests (100 kpm/min increments every minute), and also steady state exercise (SS) at 25, 50, and 75 percent of their maximum power output. The Q was determined by the indirect CO2 Fick method; mixed venous PCO2 was calculated using the exponential CO2 rebreathing method. No significant differences were observed for the cardiac output/oxygen uptake relationship (Q/VO2) obtained between the two incremental exercise tests. During NSS, the Q/VO2 was linear (r = .89; intercept = 5.69 L/min; slope = 5.39). During the SS, Q/VO2 was linear (r = .90; intercept = 5.47 L/min; slope = 4.87). No significant difference was observed between the SS and NSS Q/VO2 relationships (p greater than 0.05), and the NSS relationship was similar to Q/VO2 values previously reported in the literature. Accurate and reproducible measurements of Q can be obtained noninvasively in healthy subjects using the exponential CO2 rebreathing method during incremental progressive exercise tests, with similar values at comparable VO2 to those obtained in the steady state.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American College of Chest Physicians.