Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yamanaka, M.
Right arrow Articles by Sue, D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Yamanaka, M.
Right arrow Articles by Sue, D.

Chest, Vol 92, 832-835, Copyright © 1987 by American College of Chest Physicians


ARTICLES

Comparison of arterial-end-tidal PCO2 difference and dead space/tidal volume ratio in respiratory failure

MK Yamanaka and DY Sue
Department of Medicine, Harbor-UCLA Medical Center, Torrance 90509.

End-tidal CO2 monitors are used to estimate arterial CO2 pressure (PaCO2), but appropriate use of this noninvasive method of assessing blood gases is unclear. In patients with lung disease, the end-tidal CO2 pressure (PETCO2) can differ from PaCO2 because of ventilation- perfusion (VA/Q) mismatching, and changes in PETCO2 may be seen with corresponding increase, decrease, or no change in PaCO2 depending on what happens to VA/Q mismatching. We compared the difference between PETCO2 and PaCO2 in 17 patients undergoing mechanical ventilation. Large differences were found between PaCO2 and PETCO2 in individual patients; P(a-et)CO2 correlated closely with VD/VT. Our studies confirm that PetCO2 is a poor estimate of PaCO2 in patients with respiratory failure. However, the P(a-et)CO2 may be the most appropriate use for end-tidal PCO2 monitoring. In addition, we found that the end-tidal CO2 monitor may be easily adapted for expedient measurement of VD/VT.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
J. W. Berkenbosch, J. Lam, R. S. Burd, and J. D. Tobias
Noninvasive Monitoring of Carbon Dioxide During Mechanical Ventilation in Older Children: End-Tidal Versus Transcutaneous Techniques
Anesth. Analg., June 1, 2001; 92(6): 1427 - 1431.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
P. Seguin, J. P. Bleichner, B. Branger, Y. M. Guillou, A. Feuillu, and Y. Malledant
La pression tele expiratoire en CO2 n'est pas un parametre pertinent de surveillance d'un traumatisme cranien grave
Can J Anesth, April 1, 2001; 48(4): 396 - 400.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
Y. Tanabe, Y. Hosaka, M. Ito, E. Ito, and K. Suzuki
Significance of End-Tidal PCO2 Response to Exercise and Its Relation to Functional Capacity in Patients With Chronic Heart Failure
Chest, March 1, 2001; 119(3): 811 - 817.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. A. Sharkey, E. M.T. Mulloy, and S. J. O'Neill
The Acute Effects of Oxygen and Carbon Dioxide on Renal Vascular Resistance in Patients With an Acute Exacerbation of COPD
Chest, June 1, 1999; 115(6): 1588 - 1592.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. D. Tobias, W. R. Wilson Jr., and D. J. Meyer
Transcutaneous Monitoring of Carbon Dioxide Tension After Cardiothoracic Surgery in Infants and Children
Anesth. Analg., March 1, 1999; 88(3): 531 - 531.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American College of Chest Physicians.