Chest ACCP Career Connection
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Midei, M.
Right arrow Articles by Brinker, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Midei, M.
Right arrow Articles by Brinker, J.

Chest, Vol 94, 245-250, Copyright © 1988 by American College of Chest Physicians


ARTICLES

Double vs single balloon technique for aortic balloon valvuloplasty

MG Midei, M Brennan, GD Walford, T Aversano, SO Gottlieb and JA Brinker
Department of Medicine, Johns Hopkins Medical Institutions, Baltimore.

Percutaneous aortic valvuloplasty using a single dilating balloon has been associated with significant but modest reduction in transvalvular pressure gradient and increase in valve area. The balloon diameter is usually 20 mm or smaller to avoid disruption of aortic root structure and to permit forward blood flow during inflation. To evaluate the safety and efficacy of valvuloplasty using a combination of balloons with larger maximum inflated diameters, we compared results of aortic valvuloplasty in 21 patients using either the single or double balloon technique. Mean maximum inflated balloon diameter was 19.4 mm +/- 1.4 for the single balloon technique, while the mean sum of diameters for the simultaneous double balloon technique was 36.3 mm +/- 3.9. The mean age, aortic annulus diameter, and predilatation aortic valve area were not different among groups. Mean aortic transvalvular gradient reduction and mean aortic valve area increase were greater for the double balloon technique. The procedure was well tolerated with no major complications. No change in the degree of aortic regurgitation was noted. The double balloon technique for aortic valvuloplasty is safe and more effective at improving aortic valve area and transvalvular gradient than the conventional single balloon technique.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American College of Chest Physicians.