Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Xie, F
Right arrow Articles by Meltzer, R
Right arrow Search for Related Content
PubMed
Right arrow Articles by Xie, F
Right arrow Articles by Meltzer, R

Chest, Vol 94, 270-274, Copyright © 1988 by American College of Chest Physicians


ARTICLES

Blinded comparison of an "ultrasound stethoscope" and standard echocardiographic instrument

F Xie, MS Breese, M Nanna, GS Lichtenberg, MN Allen and R Meltzer
Department of Medicine, University of Rochester, NY.

We evaluated blinded readings by a physician using a miniature real- time "ultrasound stethoscope" compared with a "standard" echo instrument used by an independent physician. Size of all four cardiac chambers, wall motion, all four valves, thickness of interventricular septum and left ventricular posterior wall, and pericardial effusion were assessed in 66 patients. Each physician estimated whether he had answered the referring question and gave a final diagnosis. The physician using the ultrasound stethoscope correctly assessed chamber size in 87 percent of cases, segmental left ventricular wall motion in 71 percent of segments studied, and wall thickness in 88 percent of cases, and the diagnosis by the ultrasound stethoscope agreed with that made by the standard instrument in 68 percent of cases. The physician with the ultrasound stethoscope detected structural valvular problems (eg, stenosis) in 70 percent of cases but only detected flow abnormalities (eg, regurgitation) in 14 percent of cases. We conclude that (1) an experienced echocardiographer using an ultrasound stethoscope can detect most structural abnormalities found by a standard echocardiographic instrument; (2) chamber size, valvular stenosis, and pericardial effusions were accurately assessed; (3) the ultrasound stethoscope cannot be used to detect valvular regurgitation; and (4) limitations include the lack of freeze-frame, M-mode, hard copy, and Doppler.


This article has been cited by other articles:


Home page
ChestHome page
S. L. Kobal, S. Atar, and R. J. Siegel
Hand-Carried Ultrasound Improves the Bedside Cardiovascular Examination
Chest, September 1, 2004; 126(3): 693 - 701.