Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Riscili, C. E.
Right arrow Articles by Geddes, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Riscili, C. E.
Right arrow Articles by Geddes, L. A.

Chest, Vol 95, 214-217, Copyright © 1989 by American College of Chest Physicians


ARTICLES

The safety factor for electroventilation measured by production of cardiac ectopy in the anesthetized dog

CE Riscili, M Hinds, WD Voorhees, JD Bourland and LA Geddes
Hillenbrand Biomedical Engineering Center, Purdue University, West Lafayette, IN 47907.

The safety factor of electroventilation (ie, the ratio of the current required to produce an ectopic beat to the current required to produce an inspired volume of 225 ml, which is approximately twice tidal volume) was determined in 12 pentobarbital-anesthetized dogs using transthoracic electrodes positioned at the optimal electroventilation site. The optimal stimulation site for electroventilation was first determined using hand-held, stimulating electrodes. Then electrodes, 4.1 cm in diameter, were sutured bilaterally to the optimal stimulation site. The relationship between inspired volume and stimulus intensity was determined using a 0.8-s burst of stimuli (60/s) with a pulse duration of 0.1 ms. Using the same electrodes, the threshold current for producing ectopic beats was determined for single pulses ranging from 0.1 to 10 ms duration. In all dogs, the current required to produce an ectopic beat increased greatly as the pulse duration decreased. At 0.1 ms, the safety factor for electroventilation was calculated to be 25.8.