Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kerby, G.
Right arrow Articles by Koenig, G.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kerby, G.
Right arrow Articles by Koenig, G.

Chest, Vol 97, 369-372, Copyright © 1990 by American College of Chest Physicians


ARTICLES

Clinical efficacy and cost benefit of pulse flow oxygen in hospitalized patients

GR Kerby, WJ O'Donohue, DJ Romberger, FN Hanson and GA Koenig
Department of Medicine, University of Kansas School of Medicine, Kansas City 66103.

Pulse flow oxygen administered during early inspiration is a promising approach to oxygen conservation. Previous short-term studies show equivalent arterial PO2, 55 to 60 percent oxygen savings, and no reduction of nasal humidity when compared with continuous flow nasal cannula oxygen. This study compares the clinical efficacy of pulse flow and continuous flow oxygen in 100 patients recently hospitalized for diseases requiring O2 therapy. In an unblinded crossover design, pulse and continuous O2 were administered alternately during four 51/2-hour periods. Oxygen saturation was monitored continuously during the 23- hour study. Mean SaO2 on pulse flow (95.6 +/- 2.7 percent) was clinically the same as continuous flow (95.3 +/- 2.6 percent). Mean SaO2 on pulse flow during the 30 minutes before or after each crossover (95.5 +/- 3.3 percent) was similar to continuous flow during the 30 minutes near crossover (95.3 +/- 3.1 percent). It is concluded that the two delivery systems produce similar levels of SaO2 over the course of a day and night. Analysis of potential cost savings achieved by use of the device for a 350-bed hospital suggests a savings of about $50,000 yearly when accompanied by termination of oxygen humidification.


This article has been cited by other articles:


Home page
ChestHome page
A. Cuvelier, J.-F. Muir, P. Czernichow, E. Vavasseur, F. Portier, D. Benhamou, and D. Samson-Dolfuss
Nocturnal Efficiency and Tolerance of a Demand Oxygen Delivery System in COPD Patients With Nocturnal Hypoxemia
Chest, July 1, 1999; 116(1): 22 - 29.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American College of Chest Physicians.