Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Imanaka, H.
Right arrow Articles by Yoshiya, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Imanaka, H.
Right arrow Articles by Yoshiya, I.

Chest, Vol 97, 1152-1156, Copyright © 1990 by American College of Chest Physicians


ARTICLES

Measurement of functional residual capacity during high-frequency oscillatory ventilation (HFOV) by argon washout method without interruption of HFOV

H Imanaka, J Takezawa, M Nishimura, M Nishijima, N Taenaka and I Yoshiya
Intensive Care Unit, University Hospital, Osaka, Japan.

A modified indicator gas washout method was developed to measure functional residual capacity (FRC) during high-frequency oscillatory ventilation (HFOV) without interruption of HFOV. A hot-wire flowmeter and medical gas analyzer measured the flow rate and argon concentration, respectively, at the expiratory end of the respiratory circuit. Upstream of the hot-wire flowmeter, two heat-and-moisture exchangers for resistance and a rubber balloon for capacitance were placed to convert the oscillating expiratory flow to an almost continuous flow. This made it possible to measure FRC during HFOV without interrupting HFOV. To measure the volume of the entire respiratory circuit, a 10 percent argon in 90 percent oxygen gas mixture was initially used as a bias flow, and after equilibration, the test gas was switched to 100 percent oxygen. By electrical integration of the product of the expiratory flow rate and argon concentration, the total amount of argon equilibrated in the entire respiratory circuit was calculated. The volume of the circuit was calculated by dividing the total amount of argon by the initial argon concentration. Functional residual capacity plus the volume of the respiratory circuit was similarly calculated and the difference was estimated as FRC. The accuracy and reproducibility of our method were evaluated by using a one-compartment lung model. There was a high correlation between the volume setting of the model lung and the estimated FRC. This method can be used to estimate FRC in a one-compartment lung model during HFOV, and it is potentially useful in clinical situations.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the American College of Chest Physicians.