Right arrow Articles by van den Elshout, F.
Right arrow Articles by Folgering, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by van den Elshout, F.
Right arrow Articles by Folgering, H.

Chest, Vol 98, 358-364, Copyright © 1990 by American College of Chest Physicians


ARTICLES

Variations of respiratory impedance with lung volume in bronchial hyperreactivity

FJ van den Elshout, KP van de Woestijne and HT Folgering
Department of Pulmonary Diseases, University of Nijmegen, Medical Centre Dekkerswald, Groesbeek, The Netherlands.

The total respiratory impedance was measured at various frequencies (4 to 52 Hz) with a pseudo-random-noise forced oscillation technique (FOT). The apparatus (Oscillaire) was connected with a spirometer forming a closed respiratory circuit in which gas concentrations were kept constant. Measurements were made in 15 healthy subjects (group 1) and in 30 asthmatic patients with bronchial hyperreactivity, subdivided into group 2 treated only with inhaled beta 2-mimetics (n = 15) and in group 3 using both beta 2-mimetics and steroids in inhalation (n = 15). No significant differences were found between the impedance data obtained with the Oscillaire alone and those obtained with the Oscillaire connected with the spirometer circuit. The impedance was measured at FRC level, and at FRC +1 L and -1 L. The relative changes of the resistance at 8 Hz were -23.2 percent (13.8) at FRC +1 L and +40.9 percent (29.3) at FRC -1 L relative to the values at resting FRC. This inverse relation between airway resistance and lung volume was similar in all groups. The average reactance decreased at FRC -1 L in all groups. However, at FRC +1 L the average reactance increased 50.6 percent in group 2 and 94.2 percent in group 3, but decreased in group 1. Concomitant changes were observed in the resonant frequency and in the frequency dependence of resistance. Because of these qualitatively different responses of the impedance data to changes in lung volume (both for the whole group and for each individual) between healthy subjects and asthmatic patients, this test might be useful for the diagnosis of bronchial hyperreactivity.


This article has been cited by other articles:


Home page
Eur Respir JHome page
Y. F. Guo, F. Herrmann, J-P. Michel, and J-P. Janssens
Normal values for respiratory resistance using forced oscillation in subjects >65 years old
Eur. Respir. J., October 1, 2005; 26(4): 602 - 608.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
E. Oostveen, D. MacLeod, H. Lorino, R. Farre, Z. Hantos, K. Desager, and F. Marchal
The forced oscillation technique in clinical practice: methodology, recommendations and future developments
Eur. Respir. J., December 1, 2003; 22(6): 1026 - 1041.
[Abstract] [Full Text] [PDF]