Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stewart, D
Right arrow Articles by Mann, D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Stewart, D
Right arrow Articles by Mann, D.

Chest, Vol 99, 651-655, Copyright © 1991 by American College of Chest Physicians


ARTICLES

Catheter-induced tricuspid regurgitation. Incidence and clinical significance

D Stewart, RB Leman, J Kaiser and DL Mann
Cardiac Ultrasound Laboratory Charleston Veterans Administration Medical Center, SC.

The incidence and severity of catheter-induced tricuspid regurgitation has not been studied extensively. Given the frequency with which right heart catheters are employed to measure cardiac output, it is important to know whether the severity of catheter-induced tricuspid regurgitation is sufficient to invalidate the measurement of thermodilution cardiac output. Accordingly, the purpose of the present prospective study was to determine the incidence and severity of catheter-induced tricuspid regurgitation in 25 men (mean age, 58.1 +/- 1.4 years) using Doppler ultrasound. The tricuspid valve was interrogated from two orthogonal views using pulsed-wave and color flow Doppler, either in the presence or absence of a 7-French catheter across the tricuspid valve. The severity of catheter-induced tricuspid regurgitation was graded semiquantitatively using a validated scoring system. Pulsed-wave Doppler studies showed that the incidence of catheter-induced tricuspid regurgitation was 48 percent, and that the average tricuspid regurgitation score increased from 0.41 +/- 0.16 to 0.61 +/- 0.17 (p less than 0.01). Color flow Doppler studies showed similar findings. Further, the incidence of catheter-induced tricuspid regurgitation was not related to the patient's underlying hemodynamic status or right ventricular geometry. In conclusion, this study shows for the first time that the quantitative extent of catheter-induced tricuspid regurgitation is small, and is therefore unlikely to be important clinically, particularly with regard to the assessment of thermodilution cardiac output.


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
S. V. Sherman, M. H. Wall, D. J. Kennedy, R. F. Brooker, and J. Butterworth
Do Pulmonary Artery Catheters Cause or Increase Tricuspid or Pulmonic Valvular Regurgitation?
Anesth. Analg., May 1, 2001; 92(5): 1117 - 1122.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American College of Chest Physicians.