Chest Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pepin, J.
Right arrow Articles by Guilleminault, C
Right arrow Search for Related Content
PubMed
Right arrow Articles by Pepin, J.
Right arrow Articles by Guilleminault, C

Chest, Vol 99, 1151-1157, Copyright © 1991 by American College of Chest Physicians


ARTICLES

Does oximetry contribute to the detection of apneic events? Mathematical processing of the SaO2 signal

JL Pepin, P Levy, B Lepaulle, C Brambilla and C Guilleminault
Department of Pneumology and Sleep Laboratory, University Hospital, Grenoble, France.

The purpose of this study was to assess the ability of continuous nocturnal oximetry to detect sleep apnea syndrome (SAS) and to recognize nonapneic oxyhemoglobin desaturations. Oxygen saturation oscillations, related to successive apneas in SAS or to apneic episodes in COPD or restrictive patients, were quantified using a new index: delta = 1/n sigma 1 n magnitude of delta(SaO2)/delta(t)(12-s intervals) Twenty-six patients (15 SAS, 8 COPD, and 3 restrictive patients) were included in a prospective study comparing nocturnal oximetry and polysomnography over 34 nights. In apneic patients, we found a strong correlation (r2 = 0.73, p less than 0.01) between time spent in apnea and the delta index. In COPD, the number of apneas was also correlated to the delta index (r2 = 0.92, p less than 0.01). A lower threshold for delta of 1.5 is accurate enough to detect apneas if initial SaO2 is greater than 93 percent. If initial SaO2 is greater than 93 percent, the delta threshold should be 0.8 (sensitivity 95 percent). Such a method could contribute to the accurate selection of patients for polysomnography.


This article has been cited by other articles:


Home page
ChestHome page
K. E. Bloch
Getting the Most Out of Nocturnal Pulse Oximetry
Chest, November 1, 2003; 124(5): 1628 - 1630.
[Full Text] [PDF]


Home page
ChestHome page
W. W. Flemons, M. R. Littner, J. A. Rowley, P. Gay, W. M. Anderson, D. W. Hudgel, R. D. McEvoy, and D. I. Loube
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature: An Evidence Review Cosponsored by the American Academy of Sleep Medicine, the American College of Chest Physicians, and the American Thoracic Society
Chest, October 1, 2003; 124(4): 1543 - 1579.
[Full Text] [PDF]


Home page
ThoraxHome page
J A BENNETT and W J M KINNEAR
Sleep on the cheap: the role of overnight oximetry in the diagnosis of sleep apnoea hypopnoea syndrome
Thorax, November 1, 1999; 54(11): 958 - 959.
[Full Text]


Home page
ThoraxHome page
E. Chiner, J. Signes-Costa, J. M. Arriero, J. Marco, I. Fuentes, and A. Sergado
Nocturnal oximetry for the diagnosis of the sleep apnoea hypopnoea syndrome: a method to reduce the number of polysomnographies?
Thorax, November 1, 1999; 54(11): 968 - 971.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American College of Chest Physicians.