Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
First published online on March 13, 2008
Chest, doi:10.1378/chest.07-0960
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Schafroth Török, S.
Right arrow Articles by Chhajed, P. N
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schafroth Török, S.
Right arrow Articles by Chhajed, P. N

Combined Oximetry-Cutaneous Capnography in Patients Assessed for Long Term Oxygen Therapy

Salome Schafroth Török; Jörg D Leuppi; Florent Baty; Michael Tamm and Prashant N Chhajed

Pulmonary Medicine, University Hospital, Basel, Switzerland

pchhajed{at}uhbs.ch

Abstract

Study Aim: To evaluate feasibility of combined oximetry (SpO2) and cutaneous capnography (PtcCO2) for oxygen titration in patients requiring long term oxygen therapy.

Methods: 20 patients with obstructive or restrictive lung disease underwent oxygen titration using a combined cutaneous oximetry-capnography sensor.Goal of titration was to achieve oxygen saturation >90% without a significant rise in carbon dioxide. SpO2 and PtcCO2 measurements at the end of titration were compared with blood gases using Bland-Altman analysis and linear regression analysis.

Results: Mean partial pressure of arterial oxygen (PaO2) at room air was 53.2 mmHg (± 8.1 mmHg) and increased to 75.9 mmHg (± 13.3 mmHg) with oxygen supplementation (p < 0.0001). Mean partial pressure of arterial carbon dioxide (PaCO2) was 45.9 mmHg (± 8.7 mmHg) at baseline and 47.8 mmHg (± 9.0 mmHg) after oxygen titration (p = 0.003). Bland-Altman analysis for comparison of PtcCO2 and PaCO2 showed a bias of 0.86 mmHg with a precision of 3.48 mmHg. Bland-Altman analysis for the comparison of SpO2 and SaO2 showed a bias of 0.14% with a precision of 1.13%.

Conclusion: Combined oximetry and cutaneous capnography is feasible during oxygen titration in patients needing long term oxygen therapy. This non invasive approach has the potential to reduce the number of arterial blood gas sampling.

Key Words: carbon dioxide tension • cutaneous capnography • oxygen titration