Guest Access | Sign In via User Name/Password |
|||||||||
* From the Departments of Medicine (Drs. Ziegler and Loredo) and Psychiatry (Drs. Mills, Ancoli-Israel, and Dimsdale), University of California San Diego, San Diego, CA.
Correspondence to: Michael G. Ziegler, MD, UCSD Medical Center, 200 West Arbor Dr, #8341, San Diego, CA 92103; e-mail: mziegler{at}ucsd.edu
| Abstract |
|---|
|
|
|---|
Design: Randomized, placebo-controlled trial.
Setting: Patients underwent polysomnography on three occasions in a clinical research center, and had BP monitored over 24 h at home. All of the patients had sleep apnea with a respiratory disturbance index (RDI) > 15.
Interventions: The patients were randomized blindly to CPAP or placebo (CPAP at ineffective pressure) treatment.
Measurements and results: Prior to therapy, the number of apneas and the severity of nocturnal hypoxia correlated significantly with daytime urinary norepinephrine (NE) levels, but not nighttime urinary NE levels. CPAP treatment lowered daytime BP from 99 ± 2 mm Hg to 95 ± 3 mm Hg (mean ± SEM) and nighttime BP from 93 ± 3 mm Hg to 88 ± 3 mm Hg. Placebo CPAP treatment decreased both day and night mean BP only 2 mm Hg. CPAP, but not placebo, treatment lowered daytime plasma NE levels by 23%, daytime urine NE levels by 36%, daytime heart rate by 2.6 beats/min, and increased lymphocyte ß2-adrenergic receptor sensitivity (all p < 0.05). The effect of CPAP treatment on nighttime urine NE levels and heart rate did not differ from placebo treatment. There was a suggestion of an effect of placebo CPAP treatment on nighttime measures, but not on daytime measures.
Conclusion: We conclude that daytime sympathetic nervous activation is greater with more severe sleep apnea. CPAP treatment diminished the daytime sympathetic activation; the potential nighttime effect of CPAP treatment was obscured by a small placebo effect.
Key Words: ß-adrenergic receptors continuous positive airway pressure heart rate norepinephrine pulse
| Introduction |
|---|
|
|
|---|
Sleep apnea has been associated with increased sympathetic nervous activity during apneas3 and in the daytime.4 However, hypertension, obesity, and advancing age are associated with apnea and with an increase in plasma norepinephrine (NE) levels. Since enhanced sympathetic nervous activity might predispose to cardiovascular disease, establishing a link between apnea and sympathetic activity would be important. Several studies5 6 7 8 have noted a decrease in indexes of sympathetic neuronal activity following continuous positive airway pressure (CPAP) treatment of sleep apnea. While these studies have not been placebo controlled, they have been fairly consistent. Unfortunately, activities controlled by the sympathetic nerves, such as heart rate and BP, are notoriously responsive to placebo treatment, and a prescription for a mask attached to a CPAP machine may elicit a placebo response.
We conducted a blinded, placebo-controlled trial of CPAP and measured several indexes of sympathetic nervous activity in patients with sleep apnea. If CPAP treatment genuinely decreases sympathetic nervous activity, this might help explain the association between sleep apnea and cardiovascular disease and help guide decisions about the appropriate use of CPAP. A full description of the BP responses of these patients is given elsewhere.9
| Materials and Methods |
|---|
|
|
|---|
Patients receiving antihypertensive medications underwent frequent BP measurements while medicines were slowly tapered and then withheld for 3 weeks prior to study in the clinical research center. All patients underwent home monitoring (Nightwatch system; Respironics; Pittsburgh, PA) to screen for sleep apnea. Patients with a respiratory disturbance index (RDI) revealing > 20 apneic and hypopneic events per hour of sleep were eligible to continue in the study.
The patients had their pulse rate measured over 24 h using an ambulatory BP monitor (model 90207; Spacelabs Medical; Redmond, WA) prior to treatment and after 1 day and 7 days of treatment. The monitor activated every 15 min from 6 AM to 10 PM and every half hour from 10 PM to 6 AM. We used the standard Spacelabs algorithm to reject artifacts.
Patients stayed at the University of California at San Diego General Clinical Research Center for blood and urine collection, overnight polysomnography recording, central and occipital EEG, bilateral electro-oculogram, submental and tibialis anterior electromyogram, ECG, nasal/oral airflow using thermistor, and respiratory effort using chest and abdominal inductance belts. Oxyhemoglobin saturation was recorded using a pulse oximeter (Biox 3740; Ohmeda; Louisville, CO). Patients with an RDI > 15 on the inpatient polysomnogram continued in the study. On the next night, patients were randomized to receive either treatment with CPAP or placebo CPAP. Patients receiving CPAP underwent standard CPAP titration (DeVilbiss Horizon model 7353D; DeVilbiss; Somerset, PA) and a comfortably fitting mask. Pressure in the mask started at 2 cm H2O and was increased over the night by increments of 2 cm H2O until apneic episodes were obliterated or until a pressure of 8 to 10 cm H2O was reached. Further pressure titration was then done in increments of 1 cm H2O based on the presence of apnea, hypopnea, or snoring associated with arousals. The titration ended when respiratory events were controlled with CPAP.
Individuals randomized to receive placebo CPAP underwent a mock titration night; they wore a special mask that had three 1/4-inch drill holes to create a large leak through the mask. Their CPAP pressure was set at 2 cm H2O and was not advanced. All CPAP units had a hidden compliance clock that allowed measurement of the amount of time the machine was switched on. The patient and all investigators not involved in CPAP titration remained blinded as to treatment assignment. Compliance with CPAP and placebo CPAP treatment was similar. No patients familiar with CPAP were entered into the study. Patients receiving active and placebo treatments reported similar improvements in subjective well-being, suggesting that those receiving inactive CPAP were not aware of their placebo status.
On study day 1, patients arrived at the clinical research center in the afternoon and had urine collected from 5 PM to 10 PM, 10 PM to 6 AM, and 6 AM to 5 PM. Polysomnography was carried out on the evening of day 1. We collected a blood sample in the morning through an indwelling catheter after the patient rested for 20 min in a seated posture. On study day 1, patients began CPAP or placebo CPAP treatment; on study day 2 and study day 10, they continued CPAP or placebo CPAP treatment and provided repeat blood and urine samples. The 24-h urine collections were carried out on the clinical research center. We evaluated the adequacy of urine collections by measures of volume and creatinine excretion. We measured plasma and urine NE levels with a catechol-O-methyltransferase-based radioenzymatic procedure with a purification step prior to assay.10 Urine NE was normalized to body surface area by expressing it as ng/m2/h.
ß2-Adrenergic and
2-adrenergic receptor sensitivity and density
were determined at day 0 and day 11 according to previously published
methods.11
12
13
ß-Receptor sensitivity was determined in
whole lymphocytes by quantifying cyclic adenosine monophosphate (AMP)
accumulation following a 2-min incubation with 10 µmol/L
isoproterenol.
-Receptor sensitivity was determined in whole
platelets by quantifying 10 µmol/L epinephrine inhibition of 20
µmol/L prostaglandin E1-stimulated cyclic AMP
accumulation following a 2-min incubation. Cyclic AMP levels were
determined by radioimmunoassay. ß-Receptor density was determined in
lymphocyte membranes by saturation radioligand binding using
[125I]-iodopindolol. Incubations were for 60
min at 37°C. Specific binding was determined using
10-6 mol/L propranolol.
-Receptor density was
determined in platelet membranes by saturation radioligand binding
using [3H]-rauwolscine. Incubations were
for 30 min at 25°C. Specific binding was determined by using
10-5 mol/L phentolamine. We analyzed binding by a
nonlinear regression receptor-binding software program (GraphPad
Software; San Diego, CA).
Statistics
We compared groups by a two-tailed t test or
Wilcoxons rank sum test for nonnormally distributed data. We
evaluated treatment effects using the interaction term for analysis of
variance for repeated measures. The ß-receptor data were log
normalized prior to repeated-measures analysis of variance.
| Results |
|---|
|
|
|---|
|
|
|
|
|
CPAP treatment altered lymphocyte ß-receptors by increasing
ß-receptor sensitivity from 4.8 to 5.2, while the placebo group
changed from 5.1 to 4.9 (p = 0.01). ß-Receptor density followed a
similar trend but was not significant (CPAP-treated group, 70 to 82
fmol/mg protein; placebo-treated group, 79 to 76 fmol/mg protein).
-Receptor sensitivity and density were unchanged in either group
(CPAP-treated group, 0.96 to 1.2, and 32 to 29 fmol/mg protein;
placebo-treated group, 1.1 to 1.06, and 29 to 33 fmol/mg protein,
respectively).
| Discussion |
|---|
|
|
|---|
The concept that CPAP applied at night has its most apparent effect on sympathetic nervous activity in the daytime seems counterintuitive, but there is experimental support for a long-lasting effect of episodic hypoxia on the sympathetic nervous system. Rats subjected to episodic hypoxia for 7 h/d had elevated renal sympathetic nerve activity while not hypoxic.16 17 Patients with sleep apnea had increased muscle sympathetic neuronal activity in the daytime4 that decreased with CPAP treatment.7 Sleep apnea may increase daytime sympathetic nervous activity by changing cardiovascular reflexes. Sleep apnea changes baroreflex sensitivity to BP18 and chemoreflex sensitivity to oxygen19 20 in ways that enhance and prolong sympathetic neuronal responses. Although normal subjects did have BP increases in response to breathing a hypoxic gas mixture in the daytime, patients with sleep apnea had a pressor response to the same stimulus21 and a prolonged increase in sympathetic nerve activity following hypoxia.22 We have found that daytime hypoxia increased the rate of NE release into the circulation more in apneic subjects than in nonapneic subjects.23 In this study, nighttime sleep apnea elicited daytime sympathetic neuronal activation that was more prominent in our subjects than its nighttime effect. This would not have been apparent without nighttime placebo CPAP treatment. The placebo-treated group had a small decrease in nighttime urine NE level and heart rate, while there was no hint of placebo effect on daytime measures, as might be expected from a treatment applied at night. Other studies without a placebo comparison group have found that CPAP treatment decreased urinary NE levels5 and NE metabolites6 as much in the daytime as at night. Daytime studies24 25 of sympathetic nerve electrical discharge have found increased activity in sleep apnea patients compared to healthy control subjects. In addition, CPAP treatment lowers daytime sympathetic nerve activity,26 and better compliance with CPAP predicts a greater lowering of sympathetic nerve activity.27 We conclude that nocturnal CPAP treatment has at least as large an effect on daytime measures of sympathetic nervous activity as on nighttime measures.
CPAP treatment increased lymphocyte ß-receptor sensitivity, as might be expected from a treatment that lowered plasma NE levels. This finding is especially interesting since we have previously shown, both in vitro28 and in vivo,29 that patients with sleep apnea have desensitized ß-adrenergic receptors as compared to nonapneic patients. CPAP treatment normalized both NE levels and ß-receptor sensitivity. This suggests that the ß-receptor desensitization of apneic patients is a response to increased sympathetic nervous activity. Enhanced ß sensitivity may help explain the relatively small (2.6 beats/min) fall in daytime heart rate in the face of a 23% fall in plasma NE levels and a 36% fall in urine NE levels. Other studies1 2 3 4 5 6 7 8 have generally not remarked on a change in daytime heart rate with CPAP therapy, leading one to suspect that changes are generally small. This should not be taken to mean that the effects of sleep apnea and CPAP treatment on cardiac sympathetic nerves are small. Cardiac sympathetic nerves handle metaiodobenzylguanidine (MIBG) like NE. Sleep apnea patients released MIBG from the heart too fast; CPAP treatment slowed daytime cardiac MIBG turnover almost to normal.30 A small decrease in heart rate might be expected from a treatment that lowers sympathetic neuronal activity and permits ß-receptors to become more sensitive.
This study has limitations. We studied patients with sleep apnea and hypertension but without other serious illness, so the results might not apply to patients with other illnesses that commonly occur in apneic patients. The sample size was modest. However, the mock CPAP gave insight into potential placebo effects of CPAP treatment and clearly showed an effect of CPAP treatment on daytime sympathetic nervous activity. Patients with sleep apnea have an excess incidence of left and right ventricular hypertrophy,31 myocardial infarction,15 hypertension, and arrhythmia.1 The sympathetic nervous system plays a role in all of these. This study points out the need for controlled studies to see if treatment of sleep apnea can prevent cardiovascular disease.
| Footnotes |
|---|
Supported by National Institutes of Health grants HL 44915, HL 58120, and MO1-RR0827.
Received for publication May 31, 2000. Accepted for publication April 4, 2001.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
P. Haentjens, A. Van Meerhaeghe, A. Moscariello, S. De Weerdt, K. Poppe, A. Dupont, and B. Velkeniers The Impact of Continuous Positive Airway Pressure on Blood Pressure in Patients With Obstructive Sleep Apnea Syndrome: Evidence From a Meta-analysis of Placebo-Controlled Randomized Trials Arch Intern Med, April 23, 2007; 167(8): 757 - 764. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. N. Simantirakis and P. E. Vardas Cardiac pacing in sleep apnoea: diagnostic and therapeutic implications. Europace, November 1, 2006; 8(11): 984 - 987. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Sumi, K. Chin, K. Takahashi, T. Nakamura, H. Matsumoto, A. Niimi, and M. Mishima Effect of nCPAP therapy on heart rate in patients with obstructive sleep apnoea-hypopnoea QJM, August 1, 2006; 99(8): 545 - 553. [Abstract] [Full Text] [PDF] |
||||
![]() |
N S Marshall, M Barnes, N Travier, A J Campbell, R J Pierce, R D McEvoy, A M Neill, and P H Gander Continuous positive airway pressure reduces daytime sleepiness in mild to moderate obstructive sleep apnoea: a meta-analysis Thorax, May 1, 2006; 61(5): 430 - 434. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Mills, B. P. Kennedy, J. S. Loredo, J. E. Dimsdale, and M. G. Ziegler Effects of nasal continuous positive airway pressure and oxygen supplementation on norepinephrine kinetics and cardiovascular responses in obstructive sleep apnea J Appl Physiol, January 1, 2006; 100(1): 343 - 348. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. N. Simantirakis, S. E. Schiza, S. I. Chrysostomakis, G. I. Chlouverakis, N. C. Klapsinos, N. M. Siafakas, and P. E. Vardas Atrial Overdrive Pacing for the Obstructive Sleep Apnea-Hypopnea Syndrome N. Engl. J. Med., December 15, 2005; 353(24): 2568 - 2577. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. F. Haney, G. Johansson, S. Haggmark, B. Biber, M. F. Haney, G. Johansson, S. Haggmark, and B. Biber Myocardial Systolic Function Increases During Positive Pressure Lung Inflation Anesth. Analg., November 1, 2005; 101(5): 1269 - 1274. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Minoguchi, T. Tazaki, T. Yokoe, H. Minoguchi, Y. Watanabe, M. Yamamoto, and M. Adachi Elevated Production of Tumor Necrosis Factor-{alpha} by Monocytes in Patients With Obstructive Sleep Apnea Syndrome Chest, November 1, 2004; 126(5): 1473 - 1479. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. M. Oltmanns, H. Gehring, S. Rudolf, B. Schultes, S. Rook, U. Schweiger, J. Born, H. L. Fehm, and A. Peters Hypoxia Causes Glucose Intolerance in Humans Am. J. Respir. Crit. Care Med., June 1, 2004; 169(11): 1231 - 1237. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Milleron, R. Pilliere, A. Foucher, F. de Roquefeuil, P. Aegerter, G. Jondeau, B. G Raffestin, and O. Dubourg Benefits of obstructive sleep apnoea treatment in coronary artery disease: a long-term follow-up study Eur. Heart J., May 1, 2004; 25(9): 728 - 734. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. F. Quan and B. J. Gersh Cardiovascular Consequences of Sleep-Disordered Breathing: Past, Present and Future: Report of a Workshop From the National Center on Sleep Disorders Research and the National Heart, Lung, and Blood Institute Circulation, March 2, 2004; 109(8): 951 - 957. [Full Text] [PDF] |
||||
![]() |
J. Heitmann, K. Ehlenz, T. Penzel, H.F. Becker, L. Grote, K.H. Voigt, J. Hermann Peter, and C. Vogelmeier Sympathetic activity is reduced by nCPAP in hypertensive obstructive sleep apnoea patients Eur. Respir. J., February 1, 2004; 23(2): 255 - 262. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. R. Chasens, T. E. Weaver, and M. G. Umlauf Insulin Resistance and Obstructive Sleep Apnea: Is Increased Sympathetic Stimulation the Link? Biol Res Nurs, October 1, 2003; 5(2): 87 - 96. [Abstract] [PDF] |
||||
![]() |
J. o-D. L. Lattimore, D. S. Celermajer, and I. Wilcox Obstructive sleep apnea and cardiovascular disease J. Am. Coll. Cardiol., May 7, 2003; 41(9): 1429 - 1437. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Alchanatis, G. Tourkohoriti, E.N. Kosmas, G. Panoutsopoulos, S. Kakouros, K. Papadima, M. Gaga, and J.B. Jordanoglou Evidence for left ventricular dysfunction in patients with obstructive sleep apnoea syndrome Eur. Respir. J., November 1, 2002; 20(5): 1239 - 1245. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |