Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brahim, J. J.
Right arrow Articles by Rabe, K. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brahim, J. J.
Right arrow Articles by Rabe, K. F.
(Chest. 2002;121:261-263.)
© 2002 American College of Chest Physicians

Rounded Mass in the Middle Lobe After Swan-Ganz Catheterization*

Joey J. Brahim, MD; David Cheung, MD, PhD, FCCP; Jesse A. J. Jessurun, MD; Mariken J. A. Wolters-Geldof, MD and Klaus F. Rabe, MD, PhD

* From the Departments of Pulmonology (Drs. Brahim, Cheung, and Rabe), Radiology (Dr. Jessurun), and Cardiology (Dr. Wolters-Geldof), Leiden University Medical Center, Leiden, The Netherlands.

Correspondence to: Joey J. Brahim, MD, Department of Pulmonology, C3-P-18, Leiden University Medical Center, PO Box 9600, NL-2300 RC Leiden, The Netherlands; e-mail: J.J.Brahim{at}LUMC.NL


    Introduction
 TOP
 Introduction
 What is the diagnosis?
 Diagnosis:
 Discussion
 References
 

A 76 -year-old woman was admitted to the hospital because of episodes of ventricular tachycardia. She had a history of myocardial infarction in 1973 and underwent coronary artery bypass surgery in 1993. Transesophageal echocardiography revealed grade 3 mitral valve regurgitation. A left and right cardiac catheterization was performed with insertion of a Swan-Ganz catheter via the right femoral vein. Shortly after inflating the balloon in the wedge position, the patient experienced an episode of hemoptysis of approximately 50 mL. The pulmonary artery pressure was 40/20 mm Hg (mean, 21 mm Hg). Because of oxygen desaturation, she was transferred to the ICU. The chest radiograph then obtained showed a well-circumscribed rounded mass in the right middle lung zone (Fig 1 ), which was not seen on prior chest radiographs.



View larger version (66K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1.. Posteroanterior (top) and lateral (bottom) chest radiographs demonstrate a well-circumscribed rounded mass involving the middle lobe.

 

    What is the diagnosis?
 TOP
 Introduction
 What is the diagnosis?
 Diagnosis:
 Discussion
 References
 


    Diagnosis:
 TOP
 Introduction
 What is the diagnosis?
 Diagnosis:
 Discussion
 References
 
False aneurysm of the pulmonary artery induced by a Swan-Ganz catheter


    Discussion
 TOP
 Introduction
 What is the diagnosis?
 Diagnosis:
 Discussion
 References
 
Because of suspected intrapulmonary hemorrhage, a CT scan of the thorax was performed that showed a large mass in the right mid-zone with slight enhancement after contrast administration (Fig 2 ). Because the possibility of a perforation of the pulmonary artery was also considered clinically, a pulmonary angiogram was performed. Initial anteroposterior cut film angiography of the right lung was performed, injecting 30 mL of contrast medium (Iomeron 350; Bracco-Byk; Byk-Gulden, Germany) at 20 mL/s through a 7.1F Hellman angled pigtail catheter (Cordis Europe; Roden, The Netherlands). Enhancement of the lesion was prompt. A selective right interlobar pulmonary artery injection more clearly demonstrated a persistent collection of contrast arising from the medial branch of the artery of the middle pulmonary lobe, compatible with a false aneurysm (Fig 3 ). No contrast extravasation into the airways was noticed.



View larger version (118K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2.. CT images (top: mediastinal setting; bottom: parenchyma setting) through the area of the mass in the middle lobe with enhancement after contrast administration with the same attenuation as blood.

 


View larger version (174K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3.. Selective right interlobar pulmonary angiography showing the false aneurysm.

 
The pigtail catheter subsequently was exchanged over an exchange wire for a 7F headway guiding catheter with a 5F inner coaxial catheter (Nycomed; Paris, France). This catheter was advanced over an angled 0.035-inch Radiofocus guidewire (Terumo; Tokyo, Japan) into the medial branch of the middle lobe pulmonary artery. A 8 x 11-mm detachable gold valve balloon (GVB 17; Nycomed) was used to occlude the segmental artery proximal to the pseudoaneurysm. Postembolization digital pulmonary arteriogram showed successful occlusion of the segmental artery (Fig 4 ).



View larger version (89K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 4.. Selective occlusion of the feeding vessel (medial branch of the middle lobe artery) of the false aneurysm by a detachable balloon (arrow). Top: cut film. Bottom: digital subtraction angiography.

 
Pulmonary artery rupture is a rare complication of pulmonary artery Swan-Ganz catheterization (0.05 to 0.2%).1 The most common presenting symptom is hemoptysis, which can be fatal in 45 to 65% of cases. If the patient survives, a false aneurysm of the pulmonary artery may be the result, which is located most often in segmental or subsegmental branches of the right middle or lower lobe pulmonary artery. This may lead to recurrent life-threatening hemorrhage.2 Dynamic contrast-enhanced CT and pulmonary angiography are used to confirm the diagnosis.3 Transcatheter embolotherapy is the treatment of choice with lower morbidity and mortality than lobectomy. Occlusion of the pulmonary artery branches is a well-accepted method of treatment by either selective placement of coils or a detachable balloon in the feeding artery of the false aneurysm. Both occlusion methods share similar limitations and complications during the placement of the embolization device. Advantages of the detachable balloon technique are the possibility to selectively occlude the feeding vessel just proximal from the false aneurysm, without the risk of migration that can be the case with coils.4 A review article by DeLima et al2 described 92 cases of pulmonary artery rupture induced by pulmonary catheterization that led to 28 occurrences of false aneurysm. Of these, only 12 false aneurysms were detected and treated (11 by transcatheter embolotherapy) before rupture. All patients treated before rupture of the false aneurysm survived, whereas mortality was 100% in patients with rupture of false aneurysms before treatment.

Our patient survived her iatrogenic complication that happened almost 2 years ago, without having recurrent hemoptysis. The mass on her chest radiograph was no longer visible after 5 months.

In conclusion, a diagnosis of false aneurysm of the pulmonary artery should be considered in all patients who experience hemoptysis associated with Swan-Ganz catheterization.

Received for publication September 25, 2000. Accepted for publication November 21, 2000.


    References
 TOP
 Introduction
 What is the diagnosis?
 Diagnosis:
 Discussion
 References
 

  1. Boyd, KD, Thomas, SJ, Gold, J, et al (1983) A prospective study of complication of pulmonary artery catheterizations in 500 consecutive patients. Chest 84,243-249
  2. DeLima, LGR, Wynands, JE, Bourke, ME, et al (1994) Catheter-induced pulmonary artery false aneurysm and rupture: case report and review. J Cardiothorac Vasc Anesth 8,70-75[Medline]
  3. Ferretti, GR, Thony, F, Link, KM, et al (1996) False aneurysm of the pulmonary artery induced by a Swan-Ganz catheter: clinical presentation and radiologic management. AJR Am J Roentgenol 167,941-945[Abstract/Free Full Text]
  4. Remy-Jardin, M, Wattinne, L, Remy, J (1991) Transcatheter occlusion of pulmonary artery circulation and collateral supply: failures, incidents, and complications. Radiology 180,699-705[Abstract/Free Full Text]




This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brahim, J. J.
Right arrow Articles by Rabe, K. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brahim, J. J.
Right arrow Articles by Rabe, K. F.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS