* From the Departments of Respiratory Medicine (Drs. Sato, Tsukino, and Mishima) and General Medicine and Clinical Epidemiology (Dr. Koyama), Graduate School of Medicine, Kyoto University, Kyoto; Respiratory Division (Drs. Nishimura and Oga), Kyoto-Katsura Hospital, Kyoto; and Department of Pulmonary Diseases (Dr. Hajiro), Kobe Nishi City Hospital, Kobe, Japan.
Correspondence to: Susumu Sato, MD, Department of Respiratory Medicine, Graduate School of Medicine, Kyoto University, 53, Kawahara, Shogoin, Sakyo-ku, Kyoto, 606-8507, Japan; e-mail: ssato{at}kuhp.kyoto-u.ac.jp
| Abstract |
|---|
|
|
|---|
Setting: Kyoto University Hospital outpatient clinic.
Subjects and methods: Three hundred thirty-one consecutive outpatients (161 with asthma and 170 with COPD) were examined cross-sectionally by self-reported smoking status, breath CO monitoring, and serum cotinine concentration. Actual smoking status was verified by serum cotinine concentration.
Results: Mean serum cotinine concentrations of never smokers, former smokers, and current smokers with asthma were 6.0 ± 5.2 ng/mL, 12.1 ± 25.0 ng/mL, and 198.3 ± 181.7 ng/mL, respectively (± SD). Mean serum cotinine concentrations of former smokers and current smokers with COPD were 23.2 ± 69.2 ng/mL and 191.1 ± 109.8 ng/mL, respectively. Mean breath CO levels of never smokers, former smokers, and current smokers with asthma were 6.1 ± 2.4 ppm, 7.7 ± 3.2 ppm, and 19.9 ± 17.3 ppm, respectively. Mean breath CO levels of former smokers and current smokers with COPD were 7.7 ± 4.3 ppm and 13.5 ± 6.5 ppm, respectively. The optimal cutoff level of breath CO to discriminate between actual smokers and nonsmokers was 10 ppm in patients with asthma and 11 ppm in patients with COPD, giving 85.0% and 73.1% sensitivity, and 85.8% and 84.7% specificity, respectively.
Conclusion: The optimal cutoff level of breath CO to assess actual smoking status was 10 ppm in patients with stable asthma and 11 ppm in patients with stable COPD. In patients with asthma and COPD, breath CO levels were potentially influenced by underlying airway inflammation, suggesting misclassification in the assessment of smoking status by breath CO.
Key Words: asthma breath carbon monoxide COPD smoking status
| Introduction |
|---|
|
|
|---|
Self-reporting of smoking habits is widely used to estimate the prevalence of cigarette smoking, although it has been shown to underestimate smoking status.4 5 It has been suggested that the increasing social unacceptability of smoking may result in underreporting.6 Since self-reported smoking status may not be reliable in a clinical setting, a number of biochemical markers have been used to evaluate smoking status, including measures based on thiocyanate, nicotine, cotinine, and CO. These measures differ widely in availability, cost, and ease of administration.
The measurement of breath CO level may provide an immediate, noninvasive method of assessing smoking status.7 The development of relatively inexpensive portable CO monitors enables breath CO levels to be measured in a range of clinical settings. A breath CO level of 10 ppm is usually taken as the cutoff between smokers and nonsmokers. However, several studies8 9 10 11 have shown that a cutoff level of 6 or 8 ppm is more appropriate. Accordingly, breath CO monitoring devices have been updated, and the cutoff level has recently been lowered to 8 ppm.
It is known, however, that breath CO levels may be elevated due to airway inflammation. Exhaled CO levels in asthmatic patients have been reported to be high and to decrease with corticosteroid therapy.12 As such, the breath CO level may reflect intrinsic generation of CO due to oxidative stress in patients with COPD.13 14 The aims of this study were to assess the sensitivity, specificity, and reliability of breath CO monitoring, and also to assess the optimal cutoff level to distinguish smokers from nonsmokers in patients with stable asthma and COPD.
| Materials and Methods |
|---|
|
|
|---|
Methods
All patients underwent the following examination on the same day. Smoking habits were assessed during the examination by interview. Current smokers were defined as subjects who reported current, regular use of cigarettes. Former smokers were defined as subjects who had refrained from smoking for
6 months. Never smokers were defined as subjects who reported never using cigarettes. "Nonsmokers" in the content of this study means never smokers plus former smokers. Furthermore, patients with a history of nicotine patch or gum use and patients using these aids at the time of the study were excluded.
Breath CO monitoring was performed using a MICRO III Smokerlyser (Bedfont Instruments; Kent, UK), an inexpensive, portable CO monitor that has previously been shown to be useful.17 The subjects were asked to exhale completely, inhale fully, and then hold their breath for 15 s. If the subjects were unable to hold their breath for 15 s, they were asked to hold it for as long as possible. Following breath holding, the subjects were asked to exhale slowly into the Smokerlyser and were encouraged to exhale fully in order to sample the alveolar air.
All subjects had blood drawn for measurement of serum cotinine concentration and measurements were performed by gas liquid chromatography. To determine "actual" smokers, the cutoff level used was a serum cotinine concentration of > 50 ng/mL.18 The sensitivity and specificity of breath CO monitoring were calculated on the basis of cotinine levels.
Spirometric testing to determine FEV1 and FVC was performed in accordance with the method recommended by the American Thoracic Society,19 using a spirometer (AUTOSPIRO AS-600; Minato Medical Science; Osaka, Japan), which was calibrated with a 3.0-L syringe. The predicted values for the pulmonary function indexes were those proposed by the Japan Society of Chest Diseases.20
Statistical Analysis
Statistical analyses were done using StatView (SAS Institute; Cary, NC). The results are expressed as mean ± SD, unless otherwise stated. Comparisons between groups classified according to smoking status were made by the Fisher protected least-squares difference test. A discriminant analysis was performed to determine appropriate cutoff values, using receiver operating characteristic (ROC) curves.21
Spearman rank correlation coefficient was used to test the relationships between breath CO and other variables; p < 0.05 was considered statistically significant for all analyses.
| Results |
|---|
|
|
|---|
|
|
|
| Discussion |
|---|
|
|
|---|
Nineteen subjects with asthma claimed to be nonsmokers and yet had breath CO levels of > 10 ppm in the present study. Twenty-four subjects with COPD claimed to be nonsmokers and showed breath CO levels of > 11 ppm. Eleven of these patients (2 with asthma and 9 with COPD) had serum cotinine levels > 50 ng/mL. The latter would be strongly suspected to be actual current smokers who were denying their habits. Self-report classification misclassified them as nonsmokers. The incidence of misreporting of smoking status was relatively low in the literature,4 5 and would be influenced by patients knowledge of biovalidation, such as breath CO or serum cotinine monitoring.
However, the other patients (17 with asthma and 15 with COPD) were apparently genuine nonsmokers, who would be potentially misinterpreted as current smokers on the basis of breath CO monitoring. Passive smoking may elevate serum cotinine levels, but breath CO can also be elevated in this situation. The low serum cotinine and high breath CO shown by same patients may also be attributable to underlying airway inflammation and oxidative stress.12 23 At the cutoff level of 10 ppm or 11 ppm, only two patients were misclassified, apparently denying their smoking habits but showing serum cotinine levels > 50 ng/mL. If the cutoff level was lower, more nonsmoking patients may be misclassified as smokers. Using breath CO monitoring, we could detect 11 subjects (84.6%) who "actually" misreported their current smoking habit; however, 32 subjects (12.9%) who were "actual" nonsmokers had been considered as current smokers. Breath CO monitoring is an easy, noninvasive, immediate, and quite sensitive method to detect current smoking; however, it tends to provide pseudo-positive results in assessing patients with asthma or COPD.
Previous studies showed that cutoff levels of 6 ppm or 8 ppm were valid. Edward et al8 reported that 6 ppm was appropriate. While the latter study examined respiratory patients, the underlying diseases were not represented. Crowley et al9 also reported that a breath CO level of > 8 ppm was strongly associated with a self-report of current smoking. They studied only patients with COPD, however, and their survey included patients receiving home oxygen therapy, which might decrease breath CO levels. Moreover, determination of smoking status was dependent on self-reporting. Jarvis et al10 reported that the optimal cutoff was 8 ppm, giving 90% sensitivity and 89% specificity among outpatients. Terao et al11 reported that the optimal cutoff points were between 6 ppm and 7 ppm for men, and 5 ppm and 6 ppm for women with a sensitivity and a specificity of approximately 90%. The subjects of these studies were not exclusively to patients with asthma or COPD. The present study showed that the optimal cutoff level of breath CO was higher than indicated in previous studies.8 9 10 11
It has been reported that breath CO levels may be raised as a result of certain inflammatory lung diseases, such as bronchial asthma and bronchiectasis, with mean values of approximately 7 ppm.12 22 These elevations in breath CO levels due to the intrinsic generation of CO associated with oxidative stress, not only in respiratory diseases, but other diseases such as diabetes.24 In the present study, the mean breath CO level of self-reported never smokers with asthma was 7.7 ppm, and 6 of these subjects showed levels of breath CO > 10 ppm. All of these patients had cotinine levels < 50 ng/mL. These results are consistent with other studies.12 14 In the evaluation of breath CO levels in asthma and COPD in a clinical setting, the influence of airway inflammation should be considered.
Although serum cotinine is considered to be the best marker in discriminating smokers and nonsmokers,25 11 current smokers were misclassified as nonsmokers on the basis of serum cotinine levels. Serum cotinine and breath CO may also be influenced by a patients smoking style. All of them reported smoking > 10 cigarettes daily, but their smoking styles were unclear. They may smoke infrequently, and inhale little or may have stopped several days before examination, resulting in lowered serum cotinine levels. The half-life of plasma cotinine and alveolar CO are reported to be 6 to 16 h and 150 min, respectively.26 27 Six current smokers (three with asthma and three with COPD) who showed low cotinine levels and high breath CO might smoke only rarely but may have smoked recently.
The present study has certain limitations. We did not examine normal subjects, and did not obtain patient history regarding passive smoking, last cigarette smoking, or smoking patterns. These factors may influence breath CO levels and may decrease the sensitivity and specificity of breath CO monitoring. Moreover, airway obstruction may influence levels of exhaled CO. Togores et al28 reported that exhaled CO measurements can be inaccurate in patients with severe airflow obstruction. In the present study, there was no significant negative correlation between breath CO and FEV1 (percentage predicted) in nonsmokers.
Serum cotinine was used as a standard to determine smoking status. Cotinine is considered as the best choice for research protocols in which accurate categorization is essential.25 However, 11 patients (15.7%) reported to be current smokers were misclassified on the basis of serum cotinine levels. Reasons for misclassification may include the time of day of sample collection, cigarette consumption for nicotine content, and the higher cutoff value of serum cotinine used in the present study. However, additional analyses were performed using lower cutoff value (20 ng/mL) of serum cotinine in accordance with the standard by the Foundation for Blood Research and showed quite similar result for the optimal cutoff value of breath CO, though the area under the curve of ROC was smaller than that obtained using the value of 50 ng/mL.
Breath CO monitoring provides an easy, noninvasive, and immediate way of assessing patient smoking status, in contrast to the measurement of serum cotinine, which is invasive, expensive, and does not permit immediate assessment. Breath CO, however, is potentially influenced by many factors, including oxidative stress, air pollution, passive smoking, the subjects clumsiness in using the measuring device, the period of time after last smoking, the depth of smoke inhalation, the pattern of puffing, the butt length of cigarettes smoked, and so on.
| Conclusions |
|---|
|
|
|---|
Breath CO monitoring is quite useful, but in patients with airway inflammatory diseases, such as asthma and COPD, we may be at risk of misclassification in the assessment of smoking status. As such, it may be necessary to consider other factors in addition to cigarette smoking.