Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hansen, J. E.
Right arrow Articles by Wasserman, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hansen, J. E.
Right arrow Articles by Wasserman, K.
(Chest. 2004;126:816-824.)
© 2004 American College of Chest Physicians

Reproducibility of Cardiopulmonary Exercise Measurements in Patients With Pulmonary Arterial Hypertension*

James E. Hansen, MD; Xing-Guo Sun, MD; Yuji Yasunobu, MD, PhD; Robert P. Garafano, PhD; Gregory Gates, EdM; Robyn J. Barst, MD and Karlman Wasserman, PhD, MD

* From the Department of Medicine (Drs. Hansen, Sun, Yasunobu, and Wasserman), Research and Education Institute, Harbor-UCLA Medical Center, Torrance, CA; and Department of Pediatrics (Drs. Garafano, Gates, and Barst), Columbia Presbyterian Medical Center, New York, NY.

Correspondence to: James E. Hansen, MD, Box 405, Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA 90509; e-mail: jhansen{at}rei.edu


    Abstract
 TOP
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
Background and objectives: As part of a recent study, cardiopulmonary exercise tests (CPETs) were used to evaluate and follow up patients with pulmonary arterial hypertension (PAH). These patients were more impaired than those in other published series evaluating CPET reproducibility. We used these patient tests to assess patient performance variability and evaluate reading variability. To achieve this end, six independent evaluators graded key CPET measurements in patients with PAH who underwent duplicate CPETs within 3 days of each other.

Setting and patients: Over a 15-month period at two tertiary-care teaching hospitals, 42 patients with PAH underwent repeated, paired CPETs using cycle ergometry.

Interventions and measurements: Each patient underwent one to six pairs of cycle ergometry tests to maximal tolerance. Each pair of tests was separated by 3 months, with each test in the pair separated by 1 to 3 days. Specific guidelines were given to the independent evaluators for the key measurements assessed from each CPET study: peak O2 uptake (O2), peak heart rate, peak O2 pulse, anaerobic threshold (AT), and end-tidal PO2, end-tidal PCO2, and the ventilatory equivalent for CO2 at the AT (E/CO2@AT).

Results: There were no fatalities or complications occurring among the 242 tests performed on 42 patients. The mean peak O2 was 722 mL/min or 41% of predicted; 34 patients were Weber class C or D. Using the specific guidelines to measure the variability of measurements made by the six independent evaluators, the coefficients of variation were < 2.2% for peak O2, peak heart rate, peak O2 pulse, end-tidal values at the AT, and E/CO2@AT, while for the AT, it was 8.5%. There were no significant differences in these measurements between the first and second tests of any pair or between the earlier and later sets of pairs.

Conclusions: Using specific guidelines, key CPET measurements can be safely, reliably, and reproducibly assessed even in patients with severe exercise intolerance.

Key Words: anaerobic threshold • exercise testing • O2 pulse • peak O2 uptake • reproducibility • ventilatory efficiency • ventilatory equivalent for CO2


    Introduction
 TOP
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
In normal children1 and adults,23 in highly trained athletes,245 and in patients with moderate exercise impairment due to chronic disease,6789101112131415161718192021222324 repeated measurements obtained during cardiopulmonary exercise tests (CPETs) have generally shown good reliability and reproducibility. Particularly important measurements are peak O2 uptake (peak O2), which defines the maximal transport of extractable O2 to the tissues; heart rate at peak O2 (peak HR); O2 pulse at peak O2 (peak O2P), which reflects peak stroke volume and cardiac output; anaerobic threshold (AT), which assesses maximal sustainable aerobic work capacity; ventilatory equivalent for CO2 at the AT (E/CO2@AT), which is a good estimate of gas exchange abnormalities and is often described as ventilatory efficiency;25 and end-tidal CO2 value near the AT (PETCO@AT) and end-tidal O2 value near the AT (PETO2@AT), which also assess gas exchange and alveolar ventilation.

Severe disability could increase the variability and decrease the confidence of interpretation of these key CPET measurements, as suggested in one series13 that showed higher measurement variability in comparing severe to less severe heart failure. The paired CPET data from a number of patients with pulmonary artery hypertension (PAH) evaluated as part of a therapeutic study at two sites were available for evaluation. Because of the overall severity of these patients’ illness, whether assessed by Weber classification26 or percentage of predicted peak O2,27 we thought it important to evaluate the reproducibility of their key CPET measurements to ascertain if their single test values were as reliable as CPET values from less disabled patients in other reported series. Additionally, in this population, we recognized that right-to-left shunting of CO2-rich blood through a patent foramen ovale, which frequently occurs at the onset of exercise in patients with PAH, might interfere with the assessment of the AT.28

Because commercial breath-by-breath systems have differing time frames for selecting these key variables, we established predetermined rules for the use of the six study-blinded independent evaluators to record their measurements. Using paired CPETs conducted 1 to 3 days apart, we assessed not only the variability between these measurements in 228 tests (114 paired) from 42 patients (observer plus patient performance variability), but also the variability of evaluators in measuring key measurements in a single test (interobserver variability).


    Materials and Methods
 TOP
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
Subjects
This study was carried out at two sites: Harbor-UCLA Medical Center, Torrance, CA, and Columbia Presbyterian Medical Center, New York, NY. Patients with PAH had been consecutively enrolled in a therapeutic drug trial for PAH. Each patient had undergone cardiac catheterization and complete medical workup to exclude other significant disorders and to establish the diagnosis of PAH as the primary disorder. As a requirement of the study, which was approved by the Investigational Review Boards at each site, each patient had duplicate CPET performed, usually 1 day but as long as 3 days apart. Each paired set of CPET studies was repeated every 3 months in all patients for up to 15 months.

Protocol
At both sites, after familiarization with the CPET equipment, patients underwent an incremental CPET on a cycle ergometer under physician supervision, breathing through a mouthpiece with nose clipped. The protocols were identical at both sites: 3 min of sitting rest, 3 min of unloaded cycling, increasing work rate in a ramp fashion at a rate of 5 to 15 W/min (mostly 10 w/min) until symptom-limited, followed by 2 to 3 min of recovery.

Equipment and Data Display
At both sites, CPETs were performed using computercontrolled cycle ergometers with either a MedGraphics Cardiorespiratory Diagnosis System (Medical Graphics; St. Paul, MN) or a SensorMedics Vmax System (SensorMedics; Yorba Linda, CA). Calibration was done according to the instructions of the manufacturers. Gas exchange and cardiovascular data were retrieved electronically after exercise. Each exercise study was retrieved from its electronic file. The data were computer averaged for either 10-s or 15-s periods and formatted by one investigator into graphical and tabular displays at one of the sites so that the graphical displays were similar from the two sites. The data given to each grader consisted of nine-panel graphs on a single page,25 an enlarged CO2 output (CO2) vs O2 graph with equal axes on a single page for optimal discrimination of the AT by the V-slope method,29 and tabular data on one to two pages.

Data Evaluation
Each study set of three to four pages was coded, randomized, given a new identity number, and copied so that evaluators receiving the printed data were blinded as to the patients’ identities, dates of the study, their cohort, or any investigator’s prior interpretations of their studies. For each test, six evaluators, four from one site and two from the other site, agreed to independently record their numerical interpretation of the data on preprinted blank forms, following specific instructions. Each evaluator received the guidelines shown in Table 1 to determine the seven exercise measurements listed.2829 To obtain maximal stability, PETCO2@AT and E/CO2@AT values were averaged at and immediately after the AT was reached, while PETO2@AT values were averaged immediately before and at the AT.30 Evaluator experience in interpreting the AT ranged from 1 year to > 25 years.


View this table:
[in this window]
[in a new window]

 
Table 1. Guidelines for Exercise Measurements

 
The written tabular data from each of the six evaluators were collected and keyed into a new database by a single investigator. On initial evaluation, when a single datum recorded by an evaluator was found to deviate strikingly from the mean of the data of other evaluators (frequency < 1%), the possibility of a transcription or calculation error was considered. In such a circumstance, that evaluator was notified that such an error may have occurred for that single datum; the evaluator was allowed to review and resubmit the datum for that single datum. There was no feedback given to evaluators regarding their performance during their evaluation of the study data.

Statistical Analysis
Single Tests:
For the 228 exercise tests evaluated, the mean, SD, and coefficient of variation (CoV) for the group for each variable were calculated. To compare the role of investigator/evaluator experience on the variability of AT measurements, paired t tests with Bonferroni corrections were used to compare the two most experienced, two intermediate experienced, and two least experienced evaluators.

Paired Tests:
Using the above mean values and SDs for each variable for the 114 pairs of CPET studies, Pearson correlation coefficients (r) and CoV were calculated. Absolute and percentage differences between the first and second tests of each pair were summarized so that their mean and median values of the variable differences could be calculated. (For example, if the peak O2 for tests 1 and 2 in one patient were 950 mL/min and 1,050 mL/min, respectively, the mean, SD, CoV, and absolute and percentage differences would be 1,000 mL/min, 70.7 mL/min, 7.1%, 100 mL/min, and 10%, respectively.) The group mean values for each variable for the first and second of each paired test were graphed using equal X-Y coordinates according to the Bland-Altman method.31 To assess the importance of the size of the measured value, we also calculated the r, slope, and intercept values as each variable increased. Analysis of variance was performed to ascertain whether or not differences in patient age or the number of repeated paired tests caused significant trends or differences in any measurement variability; p < 0.05 was considered significant.

To assess what magnitude of differences between serial tests might be clinically significant in a single patient with severe heart or lung disease, we considered that physiologic improvement might show consistent increases in peak O2, peak O2P, AT, PETCO2@AT, and decreases in E/CO2@AT and PETO2@AT greater than those found in reproducibility of the paired tests reported here. Physiologic deterioration would show the opposite changes. Therefore, we averaged the consistent change of these six separate independent physiologic variables, all weighed equally, for each pair of tests (either improving or deteriorating), and sorted the 114 paired tests from minimal to maximal change.


    Results
 TOP
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
There was no morbidity associated with CPET; none of 228 exercise tests (114 pairs) were discarded. The patients ranged in age from 9 to 59 years and in peak O2 from 24 to 69% of predicted.25 Thirty-five of the 42 patients in the study were female (83%). All but eight were Weber class C or D (Table 2 ).


View this table:
[in this window]
[in a new window]

 
Table 2. Demographics of Study Population

 
For 228 single tests measured by the six blinded evaluators, the CoV of peak O2, peak HR, peak O2P, and PETO2@AT were < 1%, for PETCO2@AT and E/CO2@AT were approximately 2%, and for AT was 8.5% (Table 3 ). There were no significant differences or trends in variability with repeated testing.


View this table:
[in this window]
[in a new window]

 
Table 3. Mean and CoV of Seven Exercise Variables for 228 Single Tests as "Blindly" Determined by Six Evaluators

 
In assessing the AT, experienced evaluators were in better agreement with each other than those with less experience. For the two least experienced evaluators, the median absolute difference in the AT was 60 mL/min; for the two evaluators with intermediate experience, it was 40 mL/min; and for the two most experienced evaluators, it was 20 mL/min (p < 0.0001 for these comparisons). These differences between evaluators were present whether or not the patients exhibited right-to-left shunting during exercise. Further, the presence of shunting did not significantly increase or decrease the differences between evaluators.

For 114 paired CPET studies, the absolute and percentage median differences between test 1 and test 2 measurements and CoV are shown in Table 4 . The median differences and CoV both ranged from 1 to 7%.


View this table:
[in this window]
[in a new window]

 
Table 4. Median Absolute Differences and CoV in 114 Paired Tests

 
Although the scales differ, the absolute differences between paired values were all relatively small when analyzed using the Bland-Altman plots (Fig 1, 2 ). There was no order effect. For most variables, the size of the absolute differences between paired values did not change appreciably as test values increased. The size of the absolute differences between paired tests increased significantly as their values increased only for peak O2, peak O2P, and E/CO2@AT (Table 5 ). For peak O2, the absolute difference between paired tests increased by 64 mL/min for each 1,000 mL/min increase in O2, or 6.4%; for peak O2P, the absolute difference increased by < 0.04 mL/beat per 1 mL/beat increase, or 4%. For E/CO2@AT, the significant r value (r = 0.446) became insignificant (r = 0.022) when its reciprocal times a constant, which equals the PECO2@AT, was calculated (Table 5, Fig 2). Other variable differences were insignificantly affected by a change in quantity.



View larger version (33K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1. Measurements of four key exercise variables in 114 paired tests in 42 patients with PAH. Upper left: peak O2; upper right: peak HR; lower left: peak O2P; and lower right: AT. Each quadrant depicts test 1 vs test 2 values with the line of identity in the upper panel plus a Bland-Altman plot immediately below. bpm = beats per minute.

 


View larger version (30K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2. Measurements near the AT in 114 paired tests in 42 patients with PAH. Upper left: PETO2@AT; upper right: PETCO2@AT; lower left: E/CO2@AT; and lower right: PECO2@AT. Each quadrant depicts test 1 vs test 2 values with the line of identity in the upper panel plus a Bland-Altman plot immediately below.

 

View this table:
[in this window]
[in a new window]

 
Table 5. Correlation Coefficients Between Paired Exercise Tests Plus Changes in Absolute Differences as Variable Values Increased

 
In the assessment of clinically significant changes, 57 of the most highly reproducible pairs (50%) changed their average of the six physiologic measurements in a consistent direction by < 2.8%; 80 of the pairs (70%) changed by < 5.2%, and 103 of the pairs (90%) changed by < 10.0% (Fig 3 ). Neither patient age nor the number of repetitions of pairs influenced variability between paired tests.



View larger version (17K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3. Magnitude and frequency of change between 114 paired tests. The x-axis is the mean percentage change in a consistent direction for peak O2, peak O2P, AT, E/CO2@AT, PETCO2@AT, and PETO2@AT. The y-axis indicates the individual and cumulative incidence of these changes. The dashed lines indicate the 2.5%, 5%, and 10% average change for approximately 50%, 70%,and 90% of the paired tests, respectively.

 

    Discussion
 TOP
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 
Single-Test Interobserver Variability
The evaluators in this study measured most CPET values very similarly in single tests (Table 3). We believe the strict rules given as a guideline (Table 1) were important in minimizing evaluator variability. The measurements of peak O2, peak HR, peak O2P, and E/CO2@AT were especially consistent.

Measurements of the AT were more variable, even for more experienced evaluators, but the differences were relatively small even for the less experienced. In our prior experiences, AT differences between evaluators are reduced when a single evaluator has the opportunity to evaluate tests in the same patient serially or if a group of evaluators take the opportunity to discuss specific tests together. Neither of these tactics was used in this study. Subjectively, we previously had noted that AT measurement tended to be more difficult in patients who exhibit right-to-left shunting through an open foramen ovale during exercise, as the sudden increase in CO2, PETO2, and ventilatory equivalents, accompanied by a decrease in PETCO2, and usually decrease in oximetry saturation can be interpreted incorrectly as the onset of the AT, because the AT is also manifested by an increase in VCO2, R, and minute ventilation/O2.28 Thus, we were surprised to find that there was no significant increase in the variability of AT measurement in those patients that exhibited such shunting.

Paired Tests
The evaluation of paired tests in our study indicates that a single, well-performed test in a cooperative patient, even with severe or very severe exercise limitation, is valid. Despite slight differences in site equipment and technicians, time of day, patient mood, intercurrent patient illnesses, or fluctuations in disease intensity, the measured values of a second test performed 1 to 3 days later usually differed only minimally from the first test. In fact, the median differences for paired tests for all variables ranged from only 1 to 7% for peak O2, peak HR, peak O2P, AT, and E/CO2@AT (Table 4). The AT reproducibility may be especially important since some clinicians and investigators are reticent to have their patients exercise to their maximal tolerance for measurement of peak O2, peak HR, and peak O2P, and thus may choose to use the AT as a surrogate for maximal aerobic capacity.

Measurement variability was not increased at either age extreme. Also, the variability between paired tests did not significantly change from the first pair to the second, third, fourth, fifth, or sixth pair of tests. Quantitatively, the modest increase in absolute differences between paired tests for peak O2 and peak O2 pulse at higher values (Fig 2, Table 5) is not surprising. In fact, the lower absolute differences in patients with more severe disorders are salutary.

The variability of E/CO2@AT-paired differences significantly increased as their values increased from 30 to 90 U. In contrast, the variability of PECO2@AT-paired differences remained stable from 30 to 10 mm Hg (Fig 2, Table 5). The PECO2 and E/CO2 values are reciprocal. Thus, as the PECO2@AT values declined and ventilatory efficiency decreased, the variability between paired tests for E/CO2@AT significantly increased.

Factors Not Assessed
Our study did not assess the reproducibility of peak CO2, peak respiratory exchange ratio, or peak ventilation because these values are somewhat dependent on recent diet and substrate availability.11 We did not assess peak work rate, as it is more variable and also of lesser clinical utility than peak o2.26 Nevertheless, other investigators examining highly trained cyclists35 and a large number of normal adults3 found test-retest correlation coefficients > 0.86 for peak o2, peak CO2, peak ventilation, peak HR, and peak work rate. We did not assess E/O2 or E/CO2 at the peak work rate, because these values are dependent on the severity of acidemia during exercise and thus do not reflect maximal gas exchange efficiency.27 It would have been useful for us to have also assessed the nadir E/CO2 after the AT or slope of minute ventilation vs CO2, as these have variability similar to that of E/CO2@AT in a normal population.30

Clinical Relevance
The high reproducibility of the key physiologic measurements in our study compares favorably with other studies involving patients with heart, lung, musculoskeletal, or renal disease with less severe exercise impairment. For example, in 11 patients with end-stage renal disease and moderate exercise impairment (mean peak O2 of 1,500 mL/min), Koufaki et al14 reported CoVs for peak O2, peak HR, and peak O2P of 4.7%, 5.9%, and 6.0%, respectively. In an exacting study of 17 patients with mild heart disease, who were hospitalized, fasted, and tested at the same time each day, Lehmann and Kolling15 reported correlation coefficients of 0.996 for peak O2, 0.928 for peak HR, 0.991 for peak O2P, and 0.995 for E/CO2@AT. Their very high correlation coefficients can be partially attributed to the broad range of peak O2 in their patients (803 to 3,927 mL/min). In 16 cardiac patients with moderate impairment (Weber class A for 6 patients, Weber class B for 5 patients, and Weber class C for 5 patients, mean peak O2 of 26.5 mL/min/kg, 17.4 mL/min/kg, and 13.8 mL/min/kg, respectively) tested several times over a period of 3 to 22 months, Janicki et al13 found CoVs of 5.7%, 4.4%, and 9.2% for peak O2, peak HR, and AT, respectively. In duplicate tests in 11 cardiac patients (4 patients were New York Heart Association class II, and 7 patients were class III), Meyer et al,19 in patients with mean peak O2 of 13.9 mL/min/kg, found CoVs for peak O2, peak HR, and peak O2P of 4.1%, 1.4%, and 4.4%, respectively.

Several studies of CPET reproducibility in patients with obstructive or restrictive lung disease have also been reported. In triplicate tests in nine adult patients with cystic fibrosis (mean predicted peak O2 of 62%), McKone et al17 found a CoVs for peak O2 and peak HR were 6.9% and 3.0%, respectively. In triplicate tests in six patients with restrictive lung disease and predicted peak O2 of 58 ± 10%, Marciniuk et al16 found a CoVs of 5.3% for peak O2 and 4.0% for peak HR. In 11 patients with obstructive lung disease, familiar with CPET and mean peak O2 of 1.3 L/min, Brown et al6 found a CoV of 7%. In 11 patients with mild obstructive lung disease (peak O2 of 1.95 L/min), Cox et al9 reported CoVs for peak O2 and peak HR of 3% and 4%, respectively. In duplicate tests in 56 patients with COPD with a mean predicted peak O2 of 65%, Covey et al8 found correlation coefficients and CoVs of 0.97 and 4.5%, and 0.92 and 3.0%, respectively, for peak O2 and peak HR.

The patients with PAH in the current study appear to be more impaired than those in any previously reported CPET reproducibility study of patients with either cardiovascular or pulmonary diseases, as their mean ± SD percentage of predicted peak O2 was only 43 ± 10% and their Weber classes were usually severe or very severe (81% C or D). Yet, the reproducibility of their key CPET measurements remained high. Most of the studies cited above, as did ours, used cycle ergometry, which has the advantage of being under patient control and also of allowing the calculation of the O2/work rate relationship. However, for the measurements that were addressed in this study, there is no reason to expect that they would not be similarly reproducible using treadmill ergometry.

Thus we conclude that single, well-conducted gas exchange exercise tests can safely and reliably measure key and discriminating exercise variables, including peak O2, in moderately impaired to very severely impaired children and adults. The median difference in peak O2 was 7%, with lesser differences in the other measurements, all relatively independent of the absolute value. Thus, taken alone, a change in peak O2 of 8 to 10% might be used as a cut off in deciding that there is a significant change in exercise tolerance. However, using the combination of peak O2, peak O2P, AT, PETCO2@AT, E/CO2@AT, and PETO2@AT from one test to the next the average consistent change would be < 3% in half of all patients, < 5% in 7 in 10 of all patients, and < 10% in 9 in 10 of patients. To increase uniformity of reading and interpreting aerobic function and ventilatory efficiency using CPET, we recommend that other practitioners consider using the guidelines given in Table 1.


    Acknowledgements
 
The authors thank Dr. Ron Oudiz for management and referral of many of the patients, and for his assistance in study design and execution and manuscript revisions.


    Footnotes
 
Abbreviations: AT = anaerobic threshold; CoV = coefficient of variation, CPET = cardiopulmonary exercise test; peak HR = heart rate at peak O2 uptake; PAH = pulmonary arterial hypertension; peak O2P = O2 pulse at peak O2 uptake; PECO2@AT = mixed-expired pressure of CO2 at and immediately after the anaerobic threshold; PETCO2@AT = end-tidal pressure of CO2 at and immediately after the anaerobic threshold; PETO2@AT = end-tidal pressure of O2 immediately before and at the anaerobic threshold; CO2 = CO2 output; E/CO2@AT = ventilatory equivalent for CO2 at and immediately after the anaerobic threshold; O2 = O2 uptake

Received for publication October 7, 2003. Accepted for publication May 6, 2004.


    References
 TOP
 Abstract
 Introduction
 Materials and Methods
 Results
 Discussion
 References
 

  1. Figueroa-Colon, R, Hunter, GR, Mayo, MS, et al (2000) Reliability of treadmill measures and criteria to determine O2 max in prepubertal girls. Med Sci Sports Exerc 32,865-869[ISI][Medline]
  2. Astrand, PO, Rodahl, K Textbook of work physiology 3rd ed. 1986 McGraw-Hill. New York, NY:
  3. Skinner, JS, Wilmore, KM, Jaskolska, A, et al Reproducibility of maximal exercise test data in the HERITAGE family study. Med Sci Sports Exerc 1999;31,1623-1628[ISI][Medline]
  4. Weltman, A, Snead, D, Stein, P, et al Reliability and validity of a continuous incremental treadmill protocol for the determination of lactate threshold, fixed blood lactate concentrations, and O2 max. Int J Sports Med 1990;11,26-32[ISI][Medline]
  5. Weston, SB, Gabbett, TJ Reproducibility of ventilation of thresholds in trained cyclists during ramp cycle exercise. J Sci Med Sport 2001;4,357-366[CrossRef][ISI][Medline]
  6. Brown, SE, Fischer, CE, Stansbury, DW, et al Reproducibility of O2 max in patients with chronic air-flow obstruction. Am Rev Respir Dis 1985;131,435-438[ISI][Medline]
  7. Cohen-Solal, A, Zannad, F, Kayanakis, J-G, et al Multicentre study of the determination of peak oxygen uptake and ventilatory threshold during bicycle exercise in chronic heart failure. Eur Heart J 1991;12,1055-1063[Abstract/Free Full Text]
  8. Covey, MK, Larson, JL, Alex, CG, et al Test-retest reliability of symptom-limited cycle ergometer tests in patients with chronic obstructive pulmonary disease. Nurs Res 1999;48,9-19[CrossRef][ISI][Medline]
  9. Cox, NJM, Hendriks, JCM, Binkhorst, RA, et al Reproducibility of incremental maximal cycle ergometer tests in patients with mild to moderate obstructive lung diseases. Lung 1989;167,129-133[ISI][Medline]
  10. Dickstein, K, Barvik, S, Aarsland, T, et al Validation of a computerized technique for detection of the gas exchange anaerobic threshold in cardiac disease. Am J Cardiol 1990;66,1363-1367[CrossRef][ISI][Medline]
  11. Garrard, CS, Emmons, C The reproducibility of the respiratory responses to maximum exercise. Respiration 1986;49,94-100[ISI][Medline]
  12. Holland, LJ, Bhambhani, YN, Ferrara, MS, et al Reliability of the maximal aerobic power and ventilatory threshold in adults with cerebral palsy. Arch Phys Med Rehabil 1994;75,687-691[CrossRef][ISI][Medline]
  13. Janicki, JS, Gupta, S, Ferris, ST, et al Long-term reproducibility of respiratory gas exchange measurements during exercise in patients with stable cardiac failure. Chest 1990;97,12-17[Abstract/Free Full Text]
  14. Koufaki, P, Naish, PF, Mercer, TH Reproducibility of exercise tolerance in patients with end-stage renal disease. Arch Phys Med Rehabil 2001;82,1421-1424[CrossRef][ISI][Medline]
  15. Lehmann, G, Kolling, K Reproducibility of cardiopulmonary exercise parameters in patients with valvular heart disease. Chest 1996;110,685-692[Abstract/Free Full Text]
  16. Marciniuk, DD, Watts, RE, Gallagher, CG Reproducibility of incremental maximal cycle ergometer testing in patients with restrictive lung disease. Thorax 1993;48,894-898[Abstract]
  17. McKone, EF, Barry, SC, FitzGerald, MX, et al Reproducibility of maximal exercise ergometer testing in patients with cystic fibrosis. Chest 1999;116,363-368[Abstract/Free Full Text]
  18. Meyer, K, Hajric, R, Westbrook, S, et al Ventilatory and lactate threshold determinations in healthy normals and cardiac patients: methodological problems. Eur J Appl Physiol 1996;72,387-393[CrossRef]
  19. Meyer, K, Westbrook, S, Schwaibold, M, et al Short-term reproducibility of cardiopulmonary measurements during exercise testing in patients with severe chronic heart failure. Am Heart J 1997;134,20-26[CrossRef][ISI][Medline]
  20. Revill, SM, Beck, KE, Morgan, MDL Comparison of the peak exercise response measured by the ramp and 1-min step cycle exercise protocols in patients with exertional dyspnea. Chest 2002;121,1099-1105[Abstract/Free Full Text]
  21. Servera, E, Giminez, M O2 max during progressive and constant bicycle exercise in patients with chronic obstructive lung disease. Respiration 1984;45,197-206[ISI][Medline]
  22. Sullivan, MJ, Genter, F, Savvides, M, et al The reproducibility of hemodynamic electrocardiographic, and gas exchange data during treadmill exercise in patients with stable angina pectoris. Chest 1984;86,375-382[Abstract/Free Full Text]
  23. Sullivan, MJ, Cobb, FR The anaerobic threshold in chronic heart failure: relation to blood lactate, ventilatory basis, reproducibility, and response to exercise training. Circulation 1990;81,II47-II58
  24. Thin, AG, Linnane, SJ, McKone, EF, et al Use of the gas exchange threshold to noninvasively determine the lactate threshold in patients with cystic fibrosis. Chest 2002;121,1761-1770[Abstract/Free Full Text]
  25. Wasserman, K, Hansen, J, Sue, DY, et al Principles of exercise testing and interpretation 3rd ed 1999 Lippincott, Williams and Wilkins. Baltimore, MD:
  26. Weber, KT, Janicki, JS Cardiopulmonary exercise testing for evaluation of chronic cardiac failure. Am J Cardiol 1985;55,22A-31A[CrossRef][Medline]
  27. Sun, XG, Hansen, JE, Oudiz, RJ, et al Exercise pathophysiology in patients with primary pulmonary hypertension. Circulation 2001;104,429-435[Abstract/Free Full Text]
  28. Sun, X-G, Hansen, JE, Oudiz, R, et al Gas exchange detection of exercise-induced right-to-left shunt in patients with primary pulmonary hypertension. Circulation 2002;105,54-60[Abstract/Free Full Text]
  29. Beaver, WL, Wasserman, K, Whipp, BJ A new method for detecting the anaerobic threshold by gas exchange. J Appl Physiol 1986;60,2020-2027[Abstract/Free Full Text]
  30. Sun, XG, Hansen, JE, Garatachea, N, et al Ventilatory efficiency during exercise in healthy subjects. Am J Respir Crit Care Med 2002;166,1443-1448[Abstract/Free Full Text]
  31. Bland, JM, Altman, DG Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1,307-310[CrossRef][ISI][Medline]



This article has been cited by other articles:


Home page
ChestHome page
K. Wasserman, X.-G. Sun, and J. E. Hansen
Effect of Biventricular Pacing on the Exercise Pathophysiology of Heart Failure
Chest, July 1, 2007; 132(1): 250 - 261.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hansen, J. E.
Right arrow Articles by Wasserman, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hansen, J. E.
Right arrow Articles by Wasserman, K.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS