* From the Institute of Anesthesiology and Intensive Care Medicine (Drs. Hofer, Müller, Furrer, and Zollinger), Triemli City Hospital, Zurich, Switzerland; and Departments of Psychosocial Medicine (Dr. Klaghofer) and Cardiac Surgery (Dr. Genoni), University Hospital Zurich, Zurich, Switzerland.
Correspondence to: Christoph K. Hofer, MD, Institute of Anesthesiology and Intensive Care Medicine, Triemli City Hospital Birmensdorferstr. 497, CH-8063 Zurich, Switzerland; e-mail: christoph.hofer{at}triemli.stzh.ch
| Abstract |
|---|
|
|
|---|
Design: Prospective nonrandomized clinical investigation.
Setting: University-based cardiac surgery.
Patients: Forty patients with preserved left ventricular function undergoing elective off-pump coronary artery bypass grafting.
Interventions: Volume replacement therapy before surgery.
Measurements and results: Following induction of anesthesia, before and after volume replacement (6% hydroxyethyl starch solution, 10 mL/kg ideal body weight), hemodynamic measurements of stroke volume index (SVI), SVV, PPV, global end-diastolic volume index (GEDVI), central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) were obtained. Also, left ventricular end-diastolic area index (LVEDAI) was assessed by transesophageal echocardiography. Prediction of ventricular performance was tested by calculating the area under the receiver operating characteristic (ROC) curves and by linear regression analysis; p < 0.05 was considered significant. All measured hemodynamic variables except heart rate changed significantly after fluid loading. GEDVI, CVP, PCWP, and LVEDAI increased, whereas SVV and PPV decreased. The best area under the ROC curve (AUC) was found for SVV (AUC = 0.823) and PPV (AUC = 0.808); the AUC for other preload indexes ranged from 0.493 to 0.636. A significant correlation with changes of SVI was observed for SVV (r = 0.606, p < 0.001) and PPV (r = 0.612, p < 0.001) only. SVV and PPV were closely related (r = 0.861, p < 0.001).
Conclusions: In contrast to standard preload indexes, SVV and PPV, comparably, showed a good performance in predicting fluid responsiveness in patients before off-pump coronary artery bypass grafting.
Key Words: cardiac preload assessment cardiac surgery pulse contour analysis pulse pressure variation stroke volume variation
| Introduction |
|---|
|
|
|---|
volume is restored; they have shown to reliably predict changes in cardiac output (CO) related to volume replacement.567 However, both SPV and PPV are also influenced by vasomotor tone, which is supposed to be less the case with SVV; therefore, assessment of SVV is thought to be more accurate.8
An estimate of both PPV and SVV is displayed in real-time by the PiCCOplus system (Pulsion Medical Systems; Munich, Germany), a continuous CO monitoring device based on arterial pulse contour analysis.910 Conflicting results have been published regarding the clinical use of this SVV variable in cardiac surgery patients: although SVV was able to predict fluid responsiveness in patients after cardiac surgery as reported by Reuter et al,1112 Wiesenack and colleagues13 could not confirm these results in a study performed before cardiac surgery. Both PPV and SVV have been shown to be closely correlated.14 However, to our knowledge no data on comparison of these variables regarding prediction of fluid responsiveness are available.
The aim of this study was to reevaluate the value of SVV regarding the prediction of volume responsiveness and to compare it with PPV as well as the standard preload variables in a clinical setting in patients before elective off-pump coronary artery bypass grafting.
| Materials and Methods |
|---|
|
|
|---|
After application of the routine hemodynamic monitoring according to institutional standards (pulse oximetry, five-lead ECG, and noninvasive BP monitoring [CMS; Philips Medical Systems; Andover, MA]) and the insertion of arterial and peripheral IV lines, anesthesia was induced using fentanyl (10 to 30 µg/kg IV), lidocaine (1.5 mg/kg IV), and propofol (up to 2 mg/kg IV) and was maintained with propofol (1.5 to 3 mg/kg/h) and fentanyl. Neuromuscular blockade was achieved with pancuronium bromide (0.1 mg/kg IV). Following endotracheal intubation, mechanical ventilation was performed without positive end-expiratory pressure using an inspired oxygen concentration of 50% and tidal volumes of 10 mL/kg to maintain an end-expiratory PCO2 at 4 to 4.5 kPa during the study period. Effective applied mean tidal volumes were 698 ± 79 mL, and peak airway pressures ranged from 8 to 25 cm H2O (mean, 17 ± 3 cm H2O).
Hemodynamic Assessment and Study Protocol
After induction of anesthesia, a standard 7.5F pulmonary artery catheter (Swan-Ganz Thermodilution Catheter; Edwards Lifescience LLC; Irvine, CA) was introduced via right internal jugular vein access. CVP and PCWP were measured using standard transducers and displayed on the monitor (CMS; Philips Medical Systems). Pressure transducers were zeroed at midaxillary level to ambient pressure. A 4F thermistor-tipped arterial catheter (Pulsiocath; Pulsion Medical Systems) was inserted in the left femoral artery and connected to the stand-alone monitor PiCCOplus (computer version 5.2.2; Pulsion Medical Systems). Transpulmonary thermodilution measurements of 15 mL of normal iced saline solution were performed to determine CO and SV. These measurements were made by the same observer to avoid interobserver variation. Global end-diastolic volume (GEDV) is calculated from CO, mean transit time, and down-slope time of the indicator: GEDV = CO x (mean transit time down-slope time). Transpulmonary thermodilution is used to calibrate pulse contour analysis for continuous CO monitoring and SVV. SVV, as a percentage change of SV during the ventilatory cycle, is assessed according to the following equation: SVV(%) = (maximum SV minimum SV)/mean SV, where maximum and minimum SV are mean values of the four extreme values of SV during a period of 30 s, and mean SV is the average value for this time period. Additionally, using the PiCCOplus system, PPV can be determined during the same time interval: PPV(%) = (maximum pulse pressure minimum pulse pressure)/mean pulse pressure, where maximum and mean pulse pressure are mean values of the four extreme values of pulse pressure, and mean pulse pressure is the average value for this time period. The system, the related methods, and the currently used algorithm integrating aortic compliance and systemic vascular resistance have been described in detail elsewhere.915 For transesophageal echocardiography (TEE), a Philips SONOS 5500 system with an Omniplane III TEE probe (Philips Medical Systems, Andover, MA) was used. The probe was positioned to obtain the transgastric, midpapillary, short-axis view of the left ventricle. Left ventricular end-diastolic area (LVEDA) was measured by manual planimetry of the area circumscribed by the leading-edge technique of the endocardial border in this position. LVEDA was determined, recorded, and calculated by the same experienced examiner who was blinded to the results of the hemodynamic measurements throughout the study.
On completion of baseline measurements and prior to any surgical intervention, volume replacement using 6% hydroxyethyl starch solution was performed (mean molecular weight, 130,000 d/mean degree of substitution, 0.4; Voluven; Fresenius Kabi; Stans, Switzerland), 10 mL/kg ideal body weight over 20 min, resulting in applied volumes of 695 ± 65 mL. Immediately thereafter, all hemodynamic measurements including TEE were repeated.
Data Analysis
All hemodynamic variables were recorded as mean of three repeated measurements, and CO, SV, GEDV, and LVEDA were post hoc indexed to body surface area using the "du Bois formula" (body surface area = body weight [kilograms]0.425 x body length [centimeters]0.725 x 71.84).16 Statistical analysis was performed using statistical software (Statview 5.01; SAS Institute; Cary, NC; and SPSS 10.0; SPSS; Chicago, IL). A student t test was used for comparison of hemodynamic data before and after fluid bolus. A Pearson correlation between changes of SVI and changes of the different hemodynamic variables was established. Prediction of fluid responsiveness for SVV, PPV, and standard preload indexes was tested by calculating the area under the receiver operating characteristic (ROC) curve for a SV index (SVI) increase of
25% (area under the curve [AUC] = 0.5: not better than chance, no prediction possible; AUC = 1.0: best possible prediction). Furthermore, regression analysis was performed for preload variables and changes of SVI related to the fluid bolus. Comparison between SVV and PPV was done by Bland-Altman analysis and Pearson correlation. ROC curves of SVV and PPV were compared according to Hanley and McNeil.17 Linear correlations of SVV vs changes of SVI and PPV vs changes of SVI were compared using Fisher z-transformation and Hotelling Williams test. A p value < 0.05 was considered to be statistically significant. Unless otherwise stated, data are presented as mean ± SD.
| Results |
|---|
|
|
|---|
|
25% (mean, 34 ± 7%). In five patients (14%), a SVI increase
10% was observed (mean, 7 ± 3%). Mean decrease of SVV was 8 ± 4% and of PPV was 9 ± 3% (Fig 1, center, b and bottom, c). For patients with an increase of SVI
25%, SVV at baseline was 15 ± 4% and PPV was 16 ± 3%. In patients with an SVI increase
10%, SVV at baseline was 10 ± 2% and PPV was 8 ± 3%. Percentage changes (
) of SVV, PPV, GEDVI, and LVEDAI correlated significantly with
SVI, but
CVP and
PCWP did not correlate with
SVI (Table 2
). Furthermore, a significant positive correlation was found for
GEDVI with
LVEDAI (r = 0.635, p < 0.001), whereas correlations for
CVP and for
PCWP with
LVEDAI were not significant (r = 0.200, p = 0.432, and r = 0.051, p = 0.872, respectively).
|
|
12.5% at baseline, a response to subsequent fluid replacement therapy by an increase of SVI
25% could be expected with a sensitivity of 74% and a specificity of 71%. This threshold value was 13.5% for PPV (sensitivity, 72%; specificity, 72%). Only for SVV and PPV were significant correlations observed with
SVI induced by the fluid bolus (Fig 3
).
|
|
|
SVI and PPV before fluid load with
SVI (p = 0.698). | Discussion |
|---|
|
|
|---|
SVV occurs due to cyclic changes of intrathoracic pressure induced by mechanical ventilation. It has been recognized as an interesting concept for guiding fluid replacement therapy > 20 years ago.18 The major determinant of this variable is the reduced venous return during mechanical (positive pressure) inspiration. The method per se appears to visualize the individual cardiac responseie, the changes in SVrelated to myocardial contractility due to diastolic volume loading. In the presence of hypovolemia, high SVVs can be observed and the preload dependence of left ventricular function is pronounced, ie, the ventricle operates on the ascending limb of the Frank-Starling curve. During volume expansion, there is a rightward shift of left ventricular function on the Frank-Starling curve, which is thought to correspond to the observed decrease of SVV. SVVs result in concomitant changes of arterial pressure, a well-known clinical phenomenon, which can be assessed by measurement of SPV and PPV.
Both variables have been used to assess fluid responsiveness and have been shown in different investigations3719 to have sensitivity in predicting the ventricular response to fluid administration. However, PPV was found to be superior to SPV by Michard et al20 because PPV more reliably reflected changes in transmural pressures and was less influenced by extramural, ie, pleural pressure changes associated with mechanical ventilation. Similarly, Denault et al21 stated that SPV cannot be explained by changes in left ventricular volume only but may more likely reflect changes in airway and intrathoracic pressures during mechanical ventilation. In addition, both SPV and PPV may be also influenced by vasomotor tone8; furthermore, clinical use of these variables was limited due to the need for off-line quantification. The current PiCCOplus system now provides PPV on an automated real-time basis.
SVV, however, is a volume- (not pressure-) related variable derived from pulse contour analysis and is provided continuously in real-time by the PiCCOplus system. SVV was advocated to be more accurate than SPV and PPV,8 and studies in patients during sepsis state22 or undergoing neurosurgery4 demonstrated the ability of this method to predict fluid responsiveness. However, inconsistent results investigating SVV in cardiac surgery patients have been obtained: Reuter et al11 found SVV to be useful in predicting fluid responsiveness postoperatively in patients with preserved as well as with reduced left ventricular function,12 whereas Wiesenack et al13 found no correlation between SVV and SV changes during a preoperative fluid trial. These different study results may primarily be based on considerable differences in the study designs, ie, different ventilation strategies as well as fluid management protocols and different patient cardiovascular status. After all, the value of SVV to assess fluid responsiveness has been questioned.8 Interestingly, data on direct comparison of SVV with other estimates of variation in SV are sparse: in one study,23 SVV and SPV were closely correlated, and both variables showed a comparable capability to predict fluid responsiveness. SVV and PPV were well correlated in another study14; however, prediction of fluid responsiveness was not assessed. Our results now confirm the usefulness of both SVV and PPV to predict the individual cardiac response to fluid loading in the clinical setting used.
In clinical practice, distinct information regarding the cardiac response to planned fluid replacement therapy is usually hard to obtain. We found a threshold value of 12.5% for SVV and of 13.5% for PPV to induce an SVI increase
25% with fluid replacement according to the protocol (6% hydroxyethyl starch solution [mean molecular weight, 130,000 d/mean degree of substitution, 0.4]; 10 mL/kg ideal body weight over 20 min). Only few data on SVV threshold values can be found in the literature. ROC analyses have revealed a threshold value for SVV of 9.5% to induce a stepwise SVI increase of
5% in studies412 using incremental volume administration. For PPV, a threshold value of 13% to predict a change in cardiac index
15% after a single fluid bolus was described.19
In contrast to SVV and PPV, conventional static preload indexes assessed in this study failed to predict fluid responsiveness, confirming the results of previous work on this topic.324 Standard pressure preload variables (CVP and PCWP) did not adequately reflect preload status and therefore are not suitable to predict ventricular response to fluid load.225 Both volumetric variables assessed in this studyGEDVI and LVEDAImore adequately reflected changes of cardiac preload, in accordance with data of previously published work.26 However, these two preload indexes also failed to predict the reaction of the heart to fluid loading. This finding may be explained by the fact that fluid responsiveness relies more on the slope of the Frank-Starling curve than on cardiac preload itself.
With respect to practical use of SVV monitoring for guiding fluid therapy in clinical practice, the limitations of this method have to be emphasized. While monitoring SV over time, alterations in ventilatory settingsie, tidal volumes, level of positive end-expiratory pressure, respiratory rate with concomitantly increasing intrinsic positive end-expiratory pressure, intermittent spontaneous patient breathingas well as the occurrence of dysrhythmias or alterations of myocardial contractility (including pharmacologic stimulation) may render these SVV estimates unreliable. Thus, mechanical ventilation in fully sedated patients, sinus rhythm, or pacing in a fixed mode and unchanged catecholamine management are prerequisites for proper use of this dynamic monitoring tool. Furthermore, sternotomy as well as other surgical manipulations may further influence SVV readings. Some limitations of this study also have to be addressed. First, SVV and PPV were assessed by the same device and were not compared with another technique, for instance cyclic changes of aortic Doppler flow.27 Second, we did not assess myocardial contractility. Furthermore, preoperative ß-blockade in all patients may be responsible for the observed lack of heart rate response to fluid loading and may have influenced our findings. Although ß-blockade is widely used today in patients undergoing coronary artery bypass grafting or other high-risk surgeries, our findings may not directly be applicable to patients other than the population studied. Moreover, during measurements and fluid trial, no manipulations were allowed, ie, table-tilting maneuvers, catheter insertion, or surgical interventions were strictly avoided. These conditions rarely apply to clinical situations, when the decision on fluid replacement therapy has to be taken. In conclusion, SVV and PPV assessed by the PiCCOplus system showed comparably good performance in predicting fluid responsiveness in patients with preserved left ventricular function undergoing off-pump coronary artery bypass grafting.
| Footnotes |
|---|
Received for publication November 8, 2004. Accepted for publication February 15, 2005.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
P. E. Marik, M. Baram, and B. Vahid Does Central Venous Pressure Predict Fluid Responsiveness?: A Systematic Review of the Literature and the Tale of Seven Mares Chest, July 1, 2008; 134(1): 172 - 178. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Solus-Biguenet, M. Fleyfel, B. Tavernier, E. Kipnis, J. Onimus, E. Robin, G. Lebuffe, C. Decoene, F. R. Pruvot, and B. Vallet Non-invasive prediction of fluid responsiveness during major hepatic surgery Br. J. Anaesth., December 1, 2006; 97(6): 808 - 816. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Michard Volume Management Using Dynamic Parameters Chest, October 1, 2005; 128(4): 1902 - 1903. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |