Guest Access | Sign In via User Name/Password |
|||||||||
* From the Medical Clinic I, University Hospital, University of Technology, Aachen, Germany.
Correspondence to: Stefan Krüger, MD, Medizinische Klinik I, Universitätsklinik der RWTH Aachen, Pauwelstrasse 30, 52057 Aachen, Germany; e-mail: skrueger{at}lukasneuss.de
| Abstract |
|---|
|
|
|---|
Design: Prospective.
Setting: University hospital.
Patients: We studied 42 patients (mean age ± 1 SD, 62 ± 10 years) with stent restenosis and 57 patients (mean age, 61 ± 12 years) with a native coronary lesion. All patients demonstrated a single coronary lesion of intermediate severity (stenosis diameter, 40 to 70%). Determination of FFR and quantitative angiography of the stenosis were performed.
Results: Stenosis diameter was comparable in both groups (native, 52 ± 11%; stent, 52 ± 9%; not significant [NS]). FFR was lower in stent restenosis (0.77 ± 0.15 vs 0.82 ± 0.12, p < 0.05) and more often pathologic with an FFR < 0.75 (48% vs 26%, p < 0.05) compared to native coronary stenosis. However, the area under the receiver operating characteristic curve for native stenosis was 0.82 (95% confidence interval [CI], 0.71 to 0.94) and for stent restenosis was 0.84 (95% CI, 0.71 to 0.97; NS). In patients with an FFR > 0.75, there was no adverse coronary event that was related to the stented lesion in the subsequent 6 months.
Conclusions: The threshold of stenosis diameter of coronary lesions for pathologic FFR measurement (FFR < 0.75) is similar for stent restenosis and native coronary stenosis. Thus, FFR measurement seems to be applicable for decision making in patients with stent restenosis.
Key Words: coronary artery stenosis fractional flow reserve stent restenosis
| Introduction |
|---|
|
|
|---|
Fractional flow reserve (FFR) can be invasively measured in the catheter laboratory as a simple, reliable, and reproducible index of functional stenosis severity.34567 An FFR value < 0.75 reliably identifies stenosis of native coronary arteries associated with inducible ischemia.3478910 Although FFR is reported to be a valid surrogate for SPMS in stenotic native coronary arteries, its utility in patients with coronary stent restenosis is unknown. Stent restenosis differs from native coronary lesions in its morphology, histology, and geometry.1112 In a previous study,13 we examined the value of FFR compared to SPMS in patients with coronary stent restenosis. FFR measurement, SPMS, and quantitative angiography of the stent stenosis were performed in all patients. FFR showed a good diagnostic accuracy for the detection of reversible perfusion defects in SPMS, with the best cutoff value of 0.75 for FFR. We concluded that an FFR value of 0.75 is not only valid for diagnosing significant native coronary stenosis but also for stent restenosis. Thus, FFR measurement seems to be applicable for decision making in patients with stent restenosis.
In contrast to native coronary lesions, which may have an eccentric and complex cross-sectional geometry, stent restenosis is thought to have a less complex lesion geometry. Therefore, the lesion severity threshold for inducing ischemia may be higher in stent restenosis than in a native lesion. The aim of the present study was to examine the value of FFR in intermediate coronary stent restenosis compared to intermediate native coronary artery stenosis.
| Materials and Methods |
|---|
|
|
|---|
Quantitative Coronary Angiography
Digitized coronary angiograms were analyzed off-line using a computer-assisted, automated edge-detection system. The percentages of stenosis diameter, reference diameter, and minimal lumen diameter were obtained by quantitative analysis. The guiding catheter was used for calibration. End-diastolic cine frames from two or more views were analyzed per lesion, and the most severe lesion in stenosis percentage was used. Angiograms were analyzed without knowledge of clinical data or FFR results.
FFR Measurement
Immediately after diagnostic coronary angiography, coronary pressure measurement at maximum hyperemia was performed. The coronary artery was selectively engaged with a 6F catheter without side holes, and 0.2 mg nitroglycerin was administered intracoronary. A 0.014-inch pressure guide wire (RADI Medical Systems; Uppsala, Sweden) was set at zero, advanced into the coronary artery, and positioned distal to the stenosis to be measured. FFR was determined during maximum hyperemia by the ratio PD/PA, where PD represents mean coronary pressure distal to the stenosed segment measured by the pressure wire, and PA represents mean aortic pressure measured by the guiding catheter. Maximum hyperemia was induced by intracoronary adenosine (
30 µg in the right coronary artery and
40 µg in the left coronary artery).
Statistical Analysis
Values are presented as mean values ± 1 SD. All variables were tested for normal distribution by the Kolmogorov-Smirnov test. Student t test was used for comparisons of continuous variables, and
2 test was used to compare categorical data. The area under the receiver operating characteristic curve (AUROC) was utilized for discrimination. Agreement with stenosis diameter was determined for FFR, for which we used the clinically applied threshold of 0.75.3478910 The best cutoff value for stenosis diameter to predict a FFR < 0.75 was defined as the highest sum of sensitivity and specificity. All statistical tests were two tailed, and a p value < 0.05 was considered statistically significant.
| Results |
|---|
|
|
|---|
|
Relation Between Angiographic Results and FFR
Angiographic and FFR data are given in Table 2
. The percentage of stenosis diameter was not different in patients with native coronary stenosis and stent restenosis (52 ± 11% vs 52 ± 9%, not significant [NS]). However, FFR was significantly lower in patients with stent restenosis (0.77 ± 0.15 vs 0.82 ± 0.12, p < 0.05) and more often pathologic with an FFR < 0.75 (48% vs 26%, p < 0.05) compared to patients with native coronary stenosis. Patients with stent restenosis had a lower minimal lumen diameter (1.28 ± 0.56 mm vs 1.50 ± 0.55 mm, p < 0.05) and a lower vessel reference diameter (2.36 ± 0.77 mm vs 2.82 ± 0.84 mm, p < 0.05) compared to patients with native coronary stenosis.
|
|
| Discussion |
|---|
|
|
|---|
In a study14 using dipyridamole stress echocardiography, complex coronary lesion morphology was found to be more frequently associated with pathologic findings than simple coronary lesions despite similar stenosis diameter. In contrast to native coronary lesions, which may have an eccentric cross-sectional geometry, stent restenosis is thought to have a more homogenous and less complex lesion geometry.1112 Usually, a stent structure that is either round or oval is covered by a relatively smooth neointimal layer. However, in a previous myocardial scintigraphy study,2 we could not support the hypothesis that stent restenosis requires a higher angiographic stenosis diameter than native coronary lesions to result in reversible perfusion defects at SPMS. The threshold stenosis diameter of coronary lesions for reversible perfusion defects during SPMS was similar for stent restenosis and native coronary lesions. The diagnostic accuracy of angiographic variables to assess the hemodynamic significance of intermediate lesions was low in both stent and native lesions. In the present study, FFR measurement could confirm this finding, that the threshold stenosis diameter of hemodynamic relevant intermediate coronary lesions was not different in stent restenosis and native coronary stenosis.
In a second study,13 we could show that FFR supports decision making in stent restenosis. The value of FFR measurement for the prediction of reversible perfusion defects on SPMS was evaluated in patients with stent restenosis. An FFR < 0.75 predicted hemodynamic significant stent restenosis with a sensitivity of 92%. Thus, the FFR cutoff value of 0.75 was valid also for stent restenosis. If FFR was > 0.75, a conservative approach in stent restenosis was justified.
There are several potential mechanisms that could explain the lower FFR and the higher percentage of pathologic FFR in patients with stent restenosis. When evaluating FFR, only the ratio of distal to aortic pressure at maximal vasodilatation is taken into account, regardless of the flow that passes through the stenosis or the microvascular resistance. The higher prevalence, although not significant, of hypertension and diabetes in patients with native coronary stenosis can possibly serve as a confounding factor, because it is associated with a higher microvascular resistance, potentially leading to a higher FFR value.15 Lower FFR values are seen in case of a higher pressure gradient caused by a high flow rate through the stenosis, which may be attributed to the specific geometry of stent restenosis compared to native coronary lesions. Another explanation could be that the degree of stent restenosis was underestimated by angiography. It is well known from intravascular ultrasound studies12161718 that incomplete stent deployment, protruding struts, or dislocation of plaque at the entry or exit of the stent are often not recognized by angiography but can nevertheless be responsible for a pressure gradient across the stented segment. Finally, more diffuse occult disease in the remaining parts of the coronary artery might have contributed to decreased FFR in patients with stent restenosis.18
Safe deferral of percutaneous coronary intervention based on an FFR > 0.75 has been demonstrated in several studies with low event rates at follow-up. In a retrospective analysis by Bech et al,6 percutaneous coronary intervention was deferred in a group of 100 patients with intermediate stenosis if FFR was > 0.75. The clinical event rate at 18-month follow-up was significantly lower than if the percutaneous coronary intervention had been performed as initially planed. This is confirmed by our findings that in stent patients with an FFR > 0.75 there was no adverse coronary event that was related to the stented lesion at follow-up. FFR is also a strong independent predictor of adverse coronary events when measured directly after coronary stent implantation. Normalization of FFR after stenting (FFR > 0.95) is accompanied by a event rate of 4.9% at follow-up, with a strong inverse correlation between FFR after stenting and event rate.18
It is well documented that the angiographic assessment of a coronary lesion correlates poorly with its functional significance, especially in intermediate lesions. Fischer et al19 demonstrated that neither visual assessment of an angiogram by experienced interventional cardiologists nor quantitative coronary angiography can accurately predict the functional significance of most moderate coronary stenosis. Considering these data, a decision to revascularize an intermediate coronary stenosis or stent restenosis should be based on noninvasive stress testing (eg, SPMS or stress echocardiography) or on functional invasive methods such as FFR to assess the functional severity of stent restenosis.
Performing noninvasive stress testing after angiography to determine whether a native coronary stenosis or stent restenosis should be dilated delays hospital discharge. The use of FFR may obviate the need for performing noninvasive stress testing, thus reducing duration and cost of hospitalization, which is not associated with an increase in clinical event rates at follow-up.3820 Consequently, we suggest that the most effective way for managing coronary stenosis or stent restenosis of intermediate severity is to measure FFR in the same session where coronary angiography is performed and to proceed with percutaneous coronary intervention if the FFR is < 0.75.
| Footnotes |
|---|
Received for publication September 15, 2004. Accepted for publication March 28, 2005.
| References |
|---|
|
|
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |