Chest ACCP Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Evans, T. M.
Right arrow Articles by Baumann, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Evans, T. M.
Right arrow Articles by Baumann, J. M.
(Chest. 2005;128:2412-2419.)
© 2005 American College of Chest Physicians

Airway Narrowing Measured by Spirometry and Impulse Oscillometry Following Room Temperature and Cold Temperature Exercise*

Tina M. Evans, PhD, ATC; Kenneth W. Rundell, PhD; Kenneth C. Beck, PhD; Alan M. Levine, PhD and Jennifer M. Baumann, MS, RD, LDN

* From Marywood University (Drs. Evans, Rundell, and Levine, and Ms. Baumann), Scranton, PA; and Guidant Corporation (Dr. Beck), St. Paul, MN.

Correspondence to: Kenneth W. Rundell, PhD, Director, Human Performance Laboratory, Marywood University, 2300 Adams Ave, Scranton, PA 18509; e-mail: rundell{at}marywood.edu


    Abstract
 TOP
 Abstract
 Introduction
 Methods and Materials
 Results
 Discussion
 References
 
Study objective: The efficacy of using impulse oscillometry (IOS) as an indirect measure of airflow obstruction compared to spirometry after exercise challenges in the evaluation of exercise-induced bronchoconstriction (EIB) has not been fully appreciated. The objective was to compare airway responses following room temperature and cold temperature exercise challenges, and to compare whether IOS variables relate to spirometry variables.

Design: Spirometry and IOS were performed at baseline and for 20 min after challenge at 5-min intervals.

Setting: Two 6-min exercise challenges, inhaling either room temperature (22.0°C) or cold temperature (– 1°C) dry medical-grade bottled air. At least 48 h was observed between these randomly assigned challenges.

Participants: Twenty-two physically active individuals (12 women and 10 men) with probable EIB.

Interventions: Subjects performed 6 min of stationary cycle ergometry while breathing either cold or room temperature medical-grade dry bottled air. Subjects were instructed to exercise at the highest intensity sustainable for the duration of the challenge. Heart rate and kilojoules of work performed were documented to verify exercise intensity.

Measurements and results: Strong correlations were observed within testing modalities for post-room temperature and post-cold temperature exercise spirometry and IOS values. Spirometry revealed no differences in postexercise peak falls in lung function between conditions; however, IOS identified significant differences in respiratory resistance (p < 0.05), with room temperature-inspired air being more potent than cold temperature-inspired air.

Conclusions: Correlations were found between spirometric and IOS measures of change in airway function for both exercise challenges, indicating close equivalency of the methods. The challenges appeared to elicit the EIB response by a similar mechanism of water loss, and cold temperature did not have an additive effect. IOS detected a difference in degree of response between the temperatures, whereas spirometry indicated no difference, suggesting that IOS is a more sensitive measure of change in airway function.

Key Words: bronchoconstriction • dry air • eucapnic voluntary hyperventilation • exercise • impulse oscillometry • spirometry • temperature


    Introduction
 TOP
 Abstract
 Introduction
 Methods and Materials
 Results
 Discussion
 References
 
The knowledge that respiratory symptoms alone do not predict the presence of exercise-induced bronchoconstriction (EIB) justifies the need for objective testing methods for diagnosis.1 EIB, a transient narrowing of the airways during or (most often) shortly following the termination of exercise in susceptible individuals, exceeds the estimated 10 to 12% prevalence of asthma in both the general population (4 to 20%) and in the elite athlete population (11 to 50%).23 The symptoms and observable signs of EIB are varied and disparate in nature, commonly including cough, wheeze, dyspnea, chest tightness, and/or excess mucus.1

Although the precise pathophysiology of EIB is not certain, theories have been proposed that link the condition with hyperosmolarity of the bronchial epithelia, release of chemical mediators, and exchange of water and heat (reactive hyperemia) in the airway. Inspired air is warmed to body temperature and saturated with water from the airway surface liquid prior to reaching the terminal alveoli membranes. The osmotic theory holds that airway drying occurs as a consequence of exercise hyperventilation. If airway surface liquid is not replenished, resident airway cells increase in osmolarity. The reestablishment of intracellular osmolarity on cessation of exercise is proposed to cause the release of chemical mediators4 that result in smooth muscle contraction and increased mucus production, leading to the EIB response.5

EIB is most often documented by a 10% baseline to postchallenge fall in FEV1, regardless of the mode of challenge utilized to elicit the EIB response.6 Spirometry is highly dependent on correct technique,7 as the maneuver is effort dependent and requires active cooperation by the patient, which may present clinical difficulties with children and the elderly, or with cognitively impaired individuals. Impulse oscillometry (IOS) is effort independent, as brief random pressure pulses of 5 to 35 Hz (generated by a small loudspeaker mounted in series with a pneumotach) are applied during tidal breathing. The pressure-flow oscillations are superimposed on the subject’s tidal breaths, and real-time recordings are used to provide an estimate of total respiratory system impedance and its two components, resistance and reactance.8 IOS has been used to measure short-term changes in bronchial tone in bronchodilator testing9 and has been shown to correlate with FEV178101112131415 as well as airway resistance (Raw) determined by body plethysmography.1617 The IOS maneuver provides the advantages of requiring only passive cooperation during tidal breathing and does not cause respiratory fatigue.7

Although the clinical efficacy of measuring respiratory impedance using IOS as an indirect measure of airflow obstruction after methacholine challenge has been demonstrated,1014 its usefulness in measuring changes in airway caliber brought on by exercise challenges has not been established. In light of this, the purpose of this study was to compare airway responses following room temperature exercise (RTEX) and cold temperature exercise (CTEX) challenges, and to compare whether IOS variables relate to spirometry variables. To accomplish this, exercise challenges were performed at both room temperature and cold temperature in an attempt to provoke the EIB response, with baseline and postchallenge lung function being measured by both spirometry and IOS. Since IOS and spirometry measure two different outcome variables, we evaluated whether temperature affected IOS differently than spirometry. We hypothesized that the water content of the air and not temperature is a trigger for EIB, and that we would be able to identify the EIB response using IOS.


    Methods and Materials
 TOP
 Abstract
 Introduction
 Methods and Materials
 Results
 Discussion
 References
 
Subjects
Twenty-two physically active individuals with probable EIB were recruited to participate in this study (mean age ± SD, 25.2 ± 8.4 years; height, 1.71 ± 0.08 m; weight, 74.7 ± 15 kg; 10 men and 12 women). The Institutional Review Board of Marywood University approved the study protocol, and subjects provided written informed consent for participation. Eight subjects reported using an inhaled ß2-agonist prior to exercise, one subject was receiving salmeterol, one subject was receiving fluticasone in combination with salmeterol, and one subject was receiving montelukast.

Demographic/Medical History Screening Procedure
Subjects completed a demographic and medical history questionnaire prior to the study. Questionnaires were reviewed for possible safety concerns and to ensure the absence of specific exclusion criteria for this study, which included the following: participants who smoke; had an active upper respiratory tract infection within 6 weeks of testing; had an exacerbation of asthma requiring hospitalization in his or her lifetime; had received systemic steroids within 6 weeks of testing; had received the influenza vaccination within 6 weeks prior to the start of testing; had cardiovascular disease; and/or were pregnant during the time of the study.18 Participants who regularly or sporadically used asthma medications were asked to temporarily abstain from taking them prior to any testing. The specific medications and the time frames at which their use was suspended were as follows: short-acting bronchodilators, 4 h prior to any testing; long-acting or sustained-release bronchodilators; antihistamine medications; 48 h prior to any testing; leukotriene antagonists and combined long-acting bronchodilators 4 days prior to any testing.19 No physical activity or caffeine consumption was permitted for at least 8 h prior to testing. Subjects had no pulmonary complaints or evidence of upper respiratory tract or other infection during the course of the study.

Eucapnic Voluntary Hyperventilation Screening Procedure
Eucapnic voluntary hyperventilation (EVH) required subjects to breathe compressed dry gas mixture (21% O2, 5% CO2, balance N2) at a predetermined rate of 30 x baseline FEV1 (85% maximal voluntary ventilation).1920 EVH gas flowed from a cylinder through a calibrated rotameter (1110 Series Flowmeter; Brooks Instruments; Hatfield, PA) to a 300-g meteorologic reservoir balloon via high-pressure tubing. From the reservoir bag, the gas was directed to the subject via a 35-mm breathing tube, two-way nonrebreathing valve, and mouthpiece (Hans Rudolf; Kansas City, MO). Expired gas passed through a flow sensor, and minute ventilation (E) was recorded as verification of the predetermined target E (max Spectra Respiratory Analysis System Model 229D; SensorMedics; Yorba Linda, CA). Inhaled gas during the EVH challenge was at approximately 22°C, with minimal water content as compressed air from a tank containing < 3 mg H2O x L air. Those subjects identified as EIB probable by a maximal fall of ≥ 7% in FEV12122 were asked to return for a RTEX challenge and a CTEX challenge (as described below), assigned to the subjects in random order no less than 48 h but no more than 1 week later. This liberal 7% cutoff value was used to account for those subjects who may be more responsive to exercise than EVH.21

Exercise Challenges
Subjects completed 6 min of stationary cycle ergometry on an electronically braked cycle ergometer (Lode Excalibur Sport; Lode; Groningen, the Netherlands) while breathing medical-grade dry bottled air. Subjects were instructed to exercise at the highest intensity sustainable for the duration of the challenge and were verbally encouraged to give a maximal effort at all times. All subjects wore wireless heart rate monitors to verify exercise intensity (Polar Vantage XL; Polar Electro; Oy, Finland), and E was continuously monitored (max Spectra Respiratory Analysis System Model 229D; SensorMedics) throughout the challenges. Total work accumulated was recorded on completion of the challenges. Inhaled air (measured at the mouth) during the RTEX challenge and CTEX challenge was at approximately 22°C and – 1°C, respectively, with minimal water content (< 3 mg H2O x L of air). Bottled air for the CTEX challenge and gas and inhalation lines were chilled in a climate-controlled chamber of the Human Performance Laboratory for a minimum of 24 h prior to use. Inhalation air temperature was monitored at the inhalation port of the two-way nonrebreathing valve (Hans Rudolf).

Pulmonary Function Test Procedures
Raw and airway reactance in response to EVH and exercise were determined by IOS (Jaeger MS-IOS; Hoechberg, Germany; LAB Manager Software version 4.53.2, 2002) using the recommended techniques of the manufacturer. Real-time recordings of mouth pressure and flow signals pulsed through 5- to 35-Hz spectrum were superimposed over tracings of tidal breathing and displayed on a computer screen. Measurements of Raw, resonant frequency (Fres), reactance at 5 Hz (X), and low-frequency reactance area (AX; area of reactance integrated from 5 Hz up to Fres) were recorded at 5, 10, 15, and 20 min after challenge.

Pulmonary function response to EVH and exercise was determined using spirometry (immediately following the IOS maneuver) using a calibrated computerized pneumotachograph spirometer (Jaeger Masterscope PC; Hoechberg, Germany; LAB Manager Software version 4.53.2, 2002). Standard measures of pulmonary function were collected, including FVC, FEV1, and isovolume forced expiratory flow at 50% of vital capacity (FEF50) calculated from baseline FVC. FEV1/FVC ratio was calculated. The procedure for all pulmonary function tests (PFTs) included the following: (1) three normal tidal volume breaths, followed by (2) inhalation to total lung capacity, and (3) forced maximal exhalation lasting at least 6 s, terminating with (4) a final maximal inhalation. All tests were performed according to current American Thoracic Society spirometry standards.23 Resting baseline pulmonary function was established prior to each challenge by selecting the best-of-three resting PFT results based on the highest sum of FVC and FEV1. Postchallenge pulmonary function was measured at 5, 10, 15, and 20 minutes. One maneuver was performed at each postchallenge time point in an effort to minimize subject fatigue and guard against potential effects of deep inhalation.24 However, if any baseline or postchallenge time point measurement was technically unacceptable, the PFT maneuver was repeated immediately.

Statistical Analysis
Descriptive statistics for resting lung function were calculated for IOS and spirometry lung function measurements. Airway responses were analyzed by analysis of variance, followed by post hoc paired t tests when significant F values were obtained. Pearson product-moment correlations were used to evaluate relationships between resting measurements and between postchallenge falls in FVC, FEV1, FEF50, as well as Raw and airway reactance measurements determined by IOS. Analysis was performed using statistical software (Statistical Package for the Social Sciences, Version 12.0; SPSS; Chicago, IL). An {alpha} of p ≤ 0.05 was considered significant.


    Results
 TOP
 Abstract
 Introduction
 Methods and Materials
 Results
 Discussion
 References
 
Baseline Lung Function
Individual and mean resting lung function values from IOS and spirometry are presented in Table 1 . Resting FVC values were normal, ranging from 81.67 to 135.59% of predicted values. One subject demonstrated below-normal resting FEV1 (78.6% of predicted value). Five of 22 subjects (22.7%) demonstrated < 70% of predicted FEF50, suggestive of mild airflow limitation and small-airway involvement. Significant correlations were identified between resting spirometry and IOS values (p < 0.05): FVC and FEV1 correlated to Raw (r = – 0.52 and r = – 0.50, respectively), and FEV1 percentage of predicted correlated to Fres and AX (r = – 0.57 and r = – 0.44, respectively). No resting spirometric or IOS measures related to post-EVH or postexercise falls in FEV1. Resting Raw was significantly correlated to post-RTEX peak fall in FEF50 (r = – 0.46, p < 0.05). Baseline spirometry and IOS measurements were not different between the two challenges.


View this table:
[in this window]
[in a new window]

 
Table 1.. Spirometry and IOS Values at Baseline*

 
Airway Response to EVH and Exercise
No significant differences in E during RTEX and CTEX were apparent (121.3 ± 27.3 L/min and 124.7 ± 24.1 L/min, respectively; Fig 1 ), nor was the area under the curve for E during exercise different between the challenges (677.7 ± 152.6 and 676.7 ± 131.7 for RTEX and CTEX, respectively). Peak heart rate during the RTEX and CTEX challenges was not different: 179.6 ± 15.1 beats/min and 181.9 ± 13.7 beats/min. Likewise, kilojoules (kJ) of work performed during the 6-min challenges were not different (68.1 ± 22.5 kJ and 68.1 ± 24.6 kJ for RTEX and CTEX, respectively).



View larger version (13K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1.. Six-minute absolute mean E represented as 20-s mean values for the first 2 min followed by 1-min mean values for the remaining 4 min during RTEX and CTEX. Values are presented as mean ± SE.

 
No differences were observed between RTEX and CTEX in postchallenge peak percentage falls for FVC, FEV1, or FEF50 (Fig 2 , top). Figure 2, bottom, presents changes in FEV1 for 20 min after challenge in 5-min intervals. Only the 5-min postchallenge time point was significantly different, with RTEX demonstrating a greater fall in FEV1 than CTEX. RTEX also resulted in a small but statistically greater increase in Raw (p < 0.05); Fres, X, and AX were not different between challenges (Fig 3 ).



View larger version (16K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2.. Top: Postchallenge peak falls in pulmonary function as measured by spirometry for all subjects (n = 22). Values are presented as mean ± SE. Bottom: Postchallenge percentage change in FEV1 from baseline until 20 min after challenge in 5-min intervals. Values are presented as mean ± SE.

 


View larger version (16K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3.. Postchallenge percentage changes in pulmonary function as measured by impulse oscillometry. The change in Raw (cm H2O/L/s) was significantly greater for RTEX than for CTEX (p < 0.05). Values are presented as mean ± SE.

 
Figure 4 illustrates percentage changes in IOS values for 20 min after challenge in 5-min increments. Raw was significantly greater for RTEX at 5 min after challenge (p < 0.05). This finding was consistent with the postchallenge percentage change in FEV1 (as shown in Fig 2, bottom).



View larger version (13K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 4.. Postchallenge percentage change in Raw (top, A) [cm H2O/L/s], Fres (top center, B) [Hz], X (bottom center, C) [cm H2O/L/s], and AX (bottom, D) [cm H2O x L] from baseline until 20 min after challenge in 5-min intervals. Raw was significantly greater for RTEX at 5 min after challenge (p < 0.05). Values are presented as mean ± SE.

 
Relationship Between Spirometry and IOS
Strong correlations were observed within testing conditions among the postexercise percentage change values for spirometric and IOS parameters. The percentage of peak fall in FEV1 was significantly correlated to the percentage of peak fall in FVC (RTEX, r = 0.44; CTEX, r = 0.64; p < 0.05) and FEF50 (RTEX, r = 0.56; p < 0.05). Peak increase in Raw was significantly correlated to peak increases in Fres, X, and AX (RTEX, r = 0.79, r = – 0.87, and r = 0.86, respectively; CTEX, r = 0.78, r = – 0.82, and r = 0.87, respectively; p < 0.05). Peak increase in Fres was significantly correlated to peak increase in X and AX (RTEX, r = – 0.76 and r = 0.94, respectively; CTEX, r = – 0.62 and r = 0.91, respectively; p < 0.05). Peak increase in X was significantly correlated to peak AX (RTEX, r = – 0.80; CTEX, r = – 0.84, p < 0.05).

For RTEX, postchallenge peak percentage change in FEF50 was significantly correlated to peak percentage change in X (r = – 0.54). For CTEX, postchallenge peak percentage change in FEV1 was significantly correlated to peak percentage change in X (r = 0.43, p < 0.05), and postchallenge peak percentage change in FEF50 was significantly correlated to peak percentage change in Raw and peak percentage change in X (r = – 0.50 and r = 0.52, respectively; p < 0.05).


    Discussion
 TOP
 Abstract
 Introduction
 Methods and Materials
 Results
 Discussion
 References
 
In this study, we compared airway responses following randomly assigned RTEX and CTEX challenges and examined whether resting and postchallenge spirometry variables correlated with resting and postchallenge IOS variables. Six minutes of exercise while breathing dry medical-grade bottled air was a suitable challenge for inducing the EIB response.25 Heart rate during exercise and the amount of work performed indicated that the challenges were at an intensity sufficient to provoke EIB,26 and comparable E and total amount of air ventilated during RTEX and CTEX verified that the challenges were similar except for the inspired air temperature; no greater EIB response was obtained by chilling the inspired dry air.

We found a high correlation between spirometric measures of change in airway function and IOS measures of change for both exercise challenges, indicating close equivalency of the two testing methods. Interestingly, IOS detected a difference in the degree of peak response to RTEX compared to CTEX, whereas spirometry only indicated a difference at the 5-min postchallenge time point but no peak differences, suggesting that IOS is a more sensitive measure of change in airway function.

Postchallenge spirometric measurements from maximal expiratory flow volume maneuvers were compared to measurements of postchallenge airway impedance from IOS during tidal breathing. Falls in postchallenge FEV1 from baseline are considered the "gold standard" indirect measure of changes in airway caliber, as they are representative of approximately 90% of the entire flow volume curve, and are the most widely used index of EIB.26 Our results of postchallenge change in IOS variables demonstrate that IOS is an accurate and reliable measure of lung function.

In asthmatics, EIB is commonly associated with abnormalities in baseline lung function.26 In this group of subjects, resting lung function was within normal expectations, as the mean percentages of predicted values were 109.07%, 106.90%, and 96.60% for FVC, FEV1, and FEF50, respectively. Likewise, IOS values were within the normal range. As indexes of change in airway obstruction, midexpiratory flows have been reported to be valid only when vital capacity is unaltered.2627 We calculated FEF50 using baseline FVC in order to allow accurate comparisons of FEF50 to IOS values.

Both the RTEX and CTEX challenges were potent stimuli of EIB. Significant intermodality correlations were identified between resting spirometry and IOS values; however, no resting spirometry or IOS indexes correlated with the postchallenge peak fall in FEV1. This is not unexpected, as Rundell et al28 found no relationship between EIB status and baseline lung function or symptoms in elite female ice hockey players. In this study, postchallenge spirometry indexes were not significantly different between RTEX and CTEX; however, peak postchallenge Raw was significantly different between RTEX and CTEX (p < 0.05), suggesting that RTEX may be more potent than CTEX and that IOS is more sensitive to changes in airway caliber than spirometry.

Previous studies91011293031 have suggested that IOS measurements are frequency dependent, with the more pronounced changes occurring at the lower frequencies. Bisgaard and Klug10 found X at 5 Hz to be significantly more sensitive than FEV1, with several IOS indexes revealing subclinical bronchial obstruction. Buhr et al17 found X to be more discriminative than Raw in detecting impaired lung function. Goldman et al31 found that Raw and reactance over the range of low frequencies below Fres (AX) provide evidence of airflow obstruction beyond the sensitivity of spirometry. Our results indicate that peak Raw is the most sensitive of the IOS indexes, although AX demonstrated a significantly greater value for RTEX (p < 0.05) at the 5-min postchallenge time point.

Of the 22 EIB-probable subjects, 14 subjects (64%) had a fall of ≥ 10% in FEV1 after RTEX, and 12 subjects (55%) had a fall of ≥ 10% in FEV1 after CTEX. Nine of the 13 patients who were EIB positive by RTEX were positive by CTEX, and 9 of the 11 patients who were positive by CTEX were positive by RTEX. All subjects demonstrated a postchallenge increase of at least 100% from baseline Raw for both challenges, including the six subjects that had a fall in FEV1 of < 10%. Although these subjects did not meet the ≥ 10% cutoff value in FEV1 for EIB, they demonstrated elevated Raw after exercise consistent with airway obstruction, suggesting that the forced expiratory maneuver may mask changes in airway tone. Similar results were observed in measurements of Fres, X, and AX. This was not unexpected, as Assefa et al32 found that deep inspiration by children and adults resulted in a similar effect of bronchodilation in healthy persons and mild asthmatics, and bronchoconstriction in patients with moderate-to-severe asthma. Others3334 have documented similar airway responses in patients with airway hyperresponsiveness and asthma.

Although airway cooling as a mechanism of EIB holds popularity in light of the common observation that EIB worsens in cold temperatures and is more prevalent in winter sport athletes, our results suggest that water content of the air rather than temperature is essential to the EIB response, as the cold temperature inhalation challenge did not have an additive effect. Because only the inspired air was chilled and not the subjects’ faces or entire bodies, the possibility of a thermally sensitive somatic-afferent vagal-efferent reflex playing a role in airway narrowing was unlikely. A similar mechanism of water loss for the provocation of EIB during the exercise challenges is in agreement with Zeitoun et al,35 who noted that the airway surface liquid was maintained during low ventilation but not during high ventilation.

Strong correlations were observed within testing modalities for post-RTEX and post-CTEX values; baseline FVC and FEV1 correlated to baseline Raw, and baseline FEV1 percentage of predicted correlated to Fres and AX. No resting spirometric measures were related to post-RTEX or post-CTEX falls in FEV1. No significant relationships were identified between resting Raw, Fres, X, or AX and peak fall in FEV1, although resting Raw was significantly correlated to post-RTEX peak fall in FEF50. Spirometry did not identify any differences in the potency of the two challenges; however, changes in airway caliber as measured by IOS identified RTEX more potent than CTEX.

This study produced two findings that are noteworthy for clinicians. Our results indicate that IOS is indeed sensitive to changes in airway caliber following RTEX and CTEX and can be used as a surrogate to spirometry in evaluating EIB. IOS provides the advantages of requiring only passive cooperation during tidal breathing, which is well suited for the evaluation of the elderly, cognitively impaired, and children, while also not causing respiratory fatigue.7 In addition, IOS is capable of assessing both central and peripheral Raw as well as pulmonary reactance. Since X is a function of lung compliance and inertia, it can be used to evaluate the elastic properties of the lung.

Both challenges appeared to provoke EIB by a similar mechanism of water loss, as cold temperature did not have an additive effect to the response. Based on our findings, we suggest that the potential role of IOS in the evaluation of EIB is deserving of further study, and that water content of the inspired air and not temperature is critical to the EIB response.


    Footnotes
 
Abbreviations: AX = low-frequency reactance area; CTEX = cold temperature exercise; EIB = exercise-induced bronchoconstriction; EVH = eucapnic voluntary hyperventilation; FEF50 = isovolume forced expiratory flow at 50% of vital capacity; Fres = resonant frequency; IOS = impulse oscillometry system; kJ = kilojoules; PFT = pulmonary function test; Raw = airway resistance; RTEX = room temperature exercise; E = minute ventilation; X = reactance at 5 Hz

This study was supported by the American College of Sports Medicine Foundation, and performed at the Marywood University Human Performance Laboratory.

The views, opinions, and findings contained in this report are those of the authors and should not be construed as an official Marywood University position.

Received for publication February 11, 2005. Accepted for publication March 18, 2005.


    References
 TOP
 Abstract
 Introduction
 Methods and Materials
 Results
 Discussion
 References
 

  1. Rundell, KW, Im, J, Mayers, LB, et al (2003) Self-reported symptoms and exercise-induced asthma in elite athletes. Med Sci Sports Exerc 33,208-213
  2. Rundell, KW, Jenkinson, DM Exercise-induced bronchospasm in the elite athlete. Sports Med 2002;32,583-600[CrossRef][Medline]
  3. Wilber, RL, Rundell, KW, Szmdera, L, et al Incidence of exercise-induced bronchospasm in Olympic winter sport athletes. Med Sci Sports Exerc 2000;32,732-737[ISI][Medline]
  4. Anderson, SD, Daviskas, E The mechanism of exercise-induced asthma is... J Allergy Clin Immunol 2000;106,453-459[CrossRef][ISI][Medline]
  5. Anderson, SD, Argyros, GJ, Magnussen, H, et al Provocation by eucapnic voluntary hyperpnea to identify exercise induced bronchoconstriction. Br J Sports Med 2001;35,344-347[Abstract/Free Full Text]
  6. Anderson, SD, Holzer, K Exercise-induced asthma: is it the right diagnosis in elite athletes? J Allergy Clin Immunol 2000;106,419-448[CrossRef][ISI][Medline]
  7. Carvalhaes-Neto, N, Lorino, H, Gallinari, C, et al Cognitive function and assessment of lung function in the elderly. Am J Respir Crit Care Med 1995;152,1611-1615[Abstract]
  8. Ortiz, G, Menendez, R The effects of inhaled albuterol and salmeterol in 2- to 5- year-old asthmatic children as measured by impulse oscillometry. J Asthma 2002;39,531-536[CrossRef][Medline]
  9. Delacourt, C, Lorino, H, Herve-Guillot, M, et al Use of the forced oscillation technique to assess airway obstruction and reversibility in children. Am J Respir Crit Care Med 2000;161,730-736[Abstract/Free Full Text]
  10. Bisgaard, H, Klug, B Lung function measurement in awake young children. Eur Respir J 1995;8,2067-2075[Abstract]
  11. Duiverman, EJ, Neijens, HJ, Van der Snee-Van Smaalen, M, et al Comparison of forced oscillometry and forced expirations for measuring dose-related responses to inhaled methacholine in asthmatic children. Bull Eur Physiopathol Respir 1986;22,433-436[ISI][Medline]
  12. Kim, CW, Kim, JS, Park, JW, et al Clinical applications of forced oscillation techniques (FOT) in patients with bronchial asthma. Korean J Intern Med 2001;16,80-86[Medline]
  13. Schmekel, B, Smith, HJ The diagnostic capacity of forced oscillation and forced expiration techniques in identifying asthma by isocapnic hyperpnoea of cold air. Eur Respir J 1997;10,2243-2249[Abstract]
  14. Vink, GR, Arets, HGM, van der Laag, J, et al Impulse oscillometry: a measure for airway obstruction. Pediatr Pulmonol 2003;35,214-219[Medline]
  15. Zerah, F, Lorino, A, Lorino, H, et al Forced oscillation technique vs spirometry to assess bronchodilation in patients with asthma and COPD. Chest 1995;108,41-47[Abstract/Free Full Text]
  16. Klug, B, Bisgaard, H Specific airway resistance, interrupter resistance, and respiratory impedance in healthy children aged 2–7 years. Pediatr Pulmonol 1998;25,322-331[CrossRef][ISI][Medline]
  17. Buhr, W, Jorres, R, Berdel, D, et al Correspondence between forced oscillometry and body plethysmography during bronchoprovocation with carbachol in children. Pediatr Pulmonol 1990;8,280-288[ISI][Medline]
  18. Argyros, GJ, Roach, JM, Hurwitz, KM, et al Eucapnic voluntary hyperventilation as a bronchoprovocation technique: development of a standardized dosing schedule in asthmatics. Chest 1996;109,1520-1524[Abstract/Free Full Text]
  19. Anderson, SD, Argyros, GJ, Magnussen, H, et al Provocation by eucapnic voluntary hyperpnea to identify exercise induced bronchoconstriction. Br J Sports Med 2001;35,344-347[Abstract/Free Full Text]
  20. Spiering, BA, Judelson, DA, Rundell, KW An evaluation of standardizing target ventilation for eucapnic voluntary hyperventilation using FEV1. J Asthma 2004;41,759-763[Medline]
  21. Rundell, KW, Wilber, RL, Szmedra, L, et al Exercise-induced asthma screening of elite athletes: field versus laboratory exercise challenge. Med Sci Sports Exerc 2000;32,309-316[ISI][Medline]
  22. Helenius, IJ, Tikkanen, HO, Haahtela, T Occurrence of exercise induced bronchospasm in elite runners: dependence on atopy and exposure to cold air and pollen. Br J Sports Med 1998;32,125-129[Abstract/Free Full Text]
  23. Enright, PL How to make sure your spirometry tests are of good quality. Respir Care 2003;48,773-776[Medline]
  24. Beck, KC, Hyatt, RE, Mpougas, P, et al Evaluation of pulmonary resistance and maximal expiratory flow measurements during exercise in humans. J Appl Physiol 1999;86,1388-1395[Abstract/Free Full Text]
  25. Anderson, SD, Brannan, JD Methods for ‘indirect’ challenge tests including exercise, eucapnic voluntary hyperpnea, and hypertonic aerosols. Clin Rev Allergy Immunol 2003;24,27-54[CrossRef][Medline]
  26. Rundell, KW, Anderson, SD, Spiering, BA, et al Field exercise vs laboratory eucapnic voluntary hyperventilation to identify airway hyperresponsiveness in elite cold weather athletes. Chest 2004;125,909-915[Abstract/Free Full Text]
  27. Beck, KC, Offord, KP, Scanlon, PD Bronchoconstriction occurring during exercise in asthmatic subjects. Am J Respir Crit Care Med 1994;149,352-357[Abstract]
  28. Rundell, KW, Spiering, BA, Evans, TM, et al Baseline lung function, exercise-induced bronchoconstriction, and asthma-like symptoms in elite women ice hockey players. Med Sci Sports Exerc 2004;36,405-410[Medline]
  29. Delacourt, C, Lorino, H, Fuhrman, C, et al Comparison of the forced oscillation technique and the interrupter technique for assessing airway obstruction and its reversibility in children. Am J Respir Crit Care Med 2001;164,965-972[Abstract/Free Full Text]
  30. Malmberg, LP, Pelkonen,, Poussa, T, et al Determinants of respiratory system input impedance and bronchodilator response in healthy Finnish preschool children. Clin Physiol Funct Imaging 2002;22,64-71[CrossRef][ISI][Medline]
  31. Goldman, MD, Carter, R, Klein, R, et al Within- and between-day variability of respiratory impedance, using impulse oscillometry in adolescent asthmatics. Pediatr Pulmonol 2002;34,312-319[CrossRef][ISI][Medline]
  32. Assefa, D, Amin, N, Dozor, AJ Effect of deep inspiration on airway caliber in children with asthma. Pediatr Pulmonol 2004;38,406-412[CrossRef][ISI][Medline]
  33. Sekizawa, K, Yanai, M, Sasaki, H, et al Effect of a previous voluntary deep breath on laryngeal resistance in normal and asthmatic subjects. J Appl Physiol 1987;63,1406-1412[Abstract/Free Full Text]
  34. Skloot, G, Togias, A Bronchodilation and bronchoprotection by deep inspiration and their relationship to bronchial hyperresponsiveness. Clin Rev Allergy Immunol 2003;24,55-72[CrossRef][ISI][Medline]
  35. Zeitoun, M, Wilk, B, Matsuzaka, NH, et al Facial cooling enhances exercise-induced bronchoconstriction in asthmatic children Med Sci Sports Exerc 2004;36,767-771[Medline]




This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Evans, T. M.
Right arrow Articles by Baumann, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Evans, T. M.
Right arrow Articles by Baumann, J. M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS