| Abstract |
|---|
|
|
|---|
Study objective: To examine in vitro the suitability of caspofungin for aerosol administration by characterizing factors that influence efficacy and airway tolerance of aerosol delivery: physicochemical properties, aerodynamics of drug particles, and efficiency of nebulizing systems.
Design: Physicochemical characteristics of caspofungin solutions (10 mg/mL and 30 mg/mL) were analyzed: osmolality, pH, viscosity, and surface tension. A time-of-flight aerosol spectrometer API Aerosizer was used to determine aerosol particle size and distribution. Drug output was quantified by high-performance liquid chromatography assay. Nebulizer efficiency was measured by drug output and respirable fraction (percentage of aerosolized particles with a 1 to 5 µm aerodynamic diameter) and compared among three jet nebulizer/compressor systems: device 1, Micromist (Hudson RCI; Temecula, CA)/Pulmo-Aide (model 5650D; DeVilbiss; Somerset, PA); device 2, Sidestream MS 2400/Envoy model IRC 1192 (Invacare; Elyria, OH); and device 3, Pari LC Star/Proneb Ultra (Pari Respiratory Equipment; Midlothian, VA).
Measurements and results: Caspofungin requires 0.9% NaCl rather than sterile water as the diluent and addition of 0.3N NaOH buffer to adjust acidity of solutions (pH 6.17 to 6.26) in order to achieve optimal physicochemical properties for airway tolerability (osmolality, 150 to 550 milliosmol per kilogram; chloride ion, 31 to 300 mmol/L; and pH 7.4). The drug output rate increased with higher concentrations of drug solution: device 1, 4.0 mg/min vs 12.5 mg/min; device 2, 5.4 mg/min vs 14.7 mg/min; and device 3, 2.3 mg/min vs 12 mg/min, respectively. The percentage of particles within the respirable range varies depending on device and concentration of drug solutions (10 mg/mL vs 30 mg/mL): device 1, 85% vs 38%; device 2, 44% vs 57%; and device 3, 83% vs 93%, respectively.
Conclusion: Caspofungin solution with adjustments appears to have physicochemical and aerodynamic characteristics suitable for aerosolization when used with either the Pari LC Star/Proneb Ultra or Micromist/Pulmo-Aide devices. Further in vivo testing is warranted.
Key Words: aerosol antifungal Aspergillus echinocandin jet nebulizer nebulization time-of-flight aerosol spectrometer
| Introduction |
|---|
|
|
|---|
Caspofungin is the first agent of a new class, the echinocandins, to have received US Food and Drug Administration approval for the treatment of aspergillosis in patients who are refractory to or intolerant of amphotericin B and/or itraconazole, as well as for invasive candidiasis and febrile neutropenia.891011 An echinocandin derivative similar to caspofungin (L-693,989) was shown to be effective in delaying mortality from IPA when administered as an aerosol prophylactically to rats12; however, to our knowledge, aerosolized echinocandin has not been evaluated in humans. Caspofungin is a promising agent to consider for aerosol administration, in that the drug not only has significant activity against Aspergillus but also other fungal pathogens causing pneumonia in the immunocompromised hosts such as Pneumocystis carinii.89 In addition, it is relatively less toxic compared to other available agents. Its aqueous-only IV dosage form can potentially be administered as an aerosol to patients for prophylaxis in the ambulatory setting, particularly when the drug is inadequately absorbed following oral administration.89
The achievement of maximal efficacy for aerosol drug delivery has been shown to depend in part on the selection of a drug solution with optimal physical properties for aerosolization and an ideal nebulizing system.1314151617 Physical properties such as the pH, osmolality, viscosity, and chloride ion concentration of solution may affect nebulization rates, lung deposition as related to particle size, and airway tolerability.13 For example, a hypotonic or hypertonic solution in large amounts can result in mucosal irritation, while cough is regularly elicited by inhalation of solutions with an osmolality < 100 or > 1,100 milliosmol (mosm)/kg.1318 However, increasing viscosity as a result of increasing drug concentration may dramatically decrease the nebulization rate.13 In addition, the distribution of aerosol particle size generated determines the pattern of drug deposition in the respiratory tract.1517 Aerosol particle size measured in mass median aerodynamic diameter (MMAD) of 1 to 5 µm is optimal because antibiotic delivery to the site of action (peripheral airways and the alveolar region of the lung) is maximized.1517 Therefore, we determined the suitability of caspofungin solution for aerosol administration by evaluating the following: (1) selected physicochemical properties that may affect airway tolerability and nebulization efficiency, and (2) different commercial nebulizing systems on particle size distribution of the aerosols generated and output efficiency.
| Materials and Methods |
|---|
|
|
|---|
Physicochemical Properties of Solutions
Caspofungin solutions of 10 mg/mL and 30 mg/mL were analyzed for osmolality, pH, viscosity, and surface tension. All physicochemical measurements on drug solutions were performed at ambient temperature in triplicate. If necessary, solutions were adjusted using appropriate pharmaceutical buffers (ie, 0.3N NaOH to neutralize acidity) to achieve desired osmolality (150 to 550 mosm/kg), chloride ion content (31 to 300 mmol/L), and pH 7.4 within tolerable limits of the airways. Respective instruments were used to measure physicochemical properties of the solutions: osmolality (Osmette, model 5004; Precision Systems; Natick, MA), pH (Accumet, model 15; Fisher Scientific; Pittsburg, PA), viscosity (Cannon-Fensce Calibrated Viscometer; Fisher Scientific), and surface tension (Surface Tensiometer 20; Fisher Scientific).
Nebulization
The following three jet nebulizing systems were used to aerosolize drug solutions: Micromist (Hudson RCI; Temecula, CA), Sidestream MS 2400 (Invacare; Elyria, OH), and Pari LC Star (Pari Respiratory Equipment; Midlothian, VA). The first nebulizer was a disposable type for inpatient use, while the latter two were reusable types for home use. The following compressors were paired with the above nebulizers, respectively, for testing: Pulmo-Aide (model 5650D; DeVilbiss; Somerset, PA), Envoy (model IRC 1192; Invacare), and Proneb Ultra (Pari Respiratory Equipment).
The nebulizer/compressor system operating pressures and flow rates without liquid present were measured using a pressure gauge (Dwyer Capsuhelic model 4280; Dwyer Instrument Company; Michigan City, IN) and a bubble meter flow calibrator (Mini-Buck model M-30; A.P. Buck; Orlando, FL). The dry operating conditions for the respective nebulizer systems were as follows: Pulmo-Aide/Micromist, 10 pounds per square inch (psi) pressure and 6.5 L/min; Envoy/Sidestream MS 2400, 10 psi and 6.8 L/min; and Proneb Ultra/Pari LC Star, 20 psi and 3.9 L/min. The lower flow rate in spite of the higher operating pressure for the Pari LC Star was due to the smaller orifice compared to the other two nebulizers.
A fill volume of 5 mL of drug solution was nebulized for each run. Nebulization was conducted until visual observation indicated depletion of the solution to less than approximately 1 mL remaining in the nebulizer reservoir. Nebulizer output in terms of amount of drug nebulized was measured in duplicate at ambient temperature. The amount of drug nebulized equaled the difference in the weight of drug solution present in the nebulizer reservoir before and after nebulization. In addition, the amount of drug nebulized was determined by high-performance liquid chromatography assay as the difference in the amount of drug present in the nebulizer reservoir before and after nebulization.
Particle size and distributions were characterized by the API Aerosizer time-of-flight aerosol spectrometer. Aerosolized drug was conducted into a flow-through chamber of approximately 8 L in volume. Samples were drawn from the chamber at 2 L/min into the aerosol spectrometer. A 2-min sample was taken at the beginning and the end of each trial. Although capable of measuring particles at a rate of up to 105/s, the experimental conditions were chosen to limit the count rate to < 104/s to avoid coincidence errors.20 The resulting data were analyzed, displayed, and archived to an attached computer. Results included a graphic plot of particle size distribution, calculated MMAD and geometric SD, and tabulated data showing the fraction of aerosol in each of 200 size ranges from 0.1 to 200 µm. From these data, we obtained the fraction by particle mass of aerosol in the respirable size range of 1 to 5 µm aerodynamic diameter. Calibration of the aerosol spectrometer was checked at the beginning and the end of the series of experiments using monodisperse aerosols produced from polystyrene latex microsphere reference suspensions (Duke Scientific; Palo Alto, CA) nebulized from a jet nebulizer (Collison MRE, model CN24; BGI; Waltham MA).
| Results |
|---|
|
|
|---|
|
|
|
|
83% of particles in the RF compared to 44% with the Envoy/Sidestream MS 2400 system. When tested at the higher drug concentration (caspofungin, 30 mg/mL), the Pulmo-Aide/Micromist system yielded the lowest amount of drug droplets within the RF (38%). The Proneb Ultra/Pari-LC Star system performance was consistent and gave a high percentage of aerosols within the RF for both high and low drug concentrations (93% vs 83%). Based on the drug output in RF, we further compared efficiency of the three nebulizing systems by simulating delivery of 50 mg of caspofungin aerosols in the respirable range (Table 2 ). The dose was selected arbitrarily as the target for drug delivery based on the recommended dose for systemic administration. Efficiency here was measured by the least drug wastage and shortest time required to deliver the target dose in optimal range of aerosol particle size. We compared the time and amount of drug required in order to deliver the target dose within the respirable range by concentration of caspofungin solution and device. In the hospital setting where disposable nebulizers are used, the Pulmo-Aide/Micromist system appeared to be most efficient: only 59 mg of caspofungin in a 10-mg/mL concentration (5.9-mL fill volume) is required to deliver the target dose of 50 mg over 15 min. However, the Proneb Ultra/Pari-LC star system is the most efficient system when reusable nebulizers are used in the home setting: only 54 mg of caspofungin in 30-mg/mL concentration (1.8-mL fill volume) is required for nebulization over 5 min to deliver the target dose.
|
| Discussion |
|---|
|
|
|---|
Caspofungin, a new antifungal agent with proven efficacy for the treatment of invasive aspergillosis, has ideal potential as an aerosol for the prevention of pulmonary aspergillosis in immunocompromised hosts. While the prophylactic potential of another derivative in the same class as caspofungin has been demonstrated in a rat model of pulmonary aspergillosis,12 to our knowledge, inhaled caspofungin therapy has not been evaluated in humans. The suitability of caspofungin for aerosol administration is important to determine in vitro with respect to factors that can influence efficacy and airway tolerance of this route of drug delivery before clinical trials in humans is undertaken.
We evaluated the suitability of caspofungin for aerosol administration by performing in vitro testing to characterize the aerodynamic behavior of the particles and efficiency of the devices used for nebulization. Among other factors such as nebulizer brand and flow rate, the volume of diluent has been shown to affect nebulization time.21 A reasonable nebulization time (< 30 min) for delivery of the intended drug output is an important practical consideration for patient compliance in the outpatient setting and clinician supervision of hospitalized patients.22 Increased fill volume can reduce the amount of drug trapped in the nebulizer cup but requires a longer nebulization time; however, the time of nebulization can be offset by the use of a device with higher flow rates. We arbitrarily tested caspofungin solutions in two drug concentrations, 10 mg/mL and 30 mg/mL, to allow delivery of a dose of 50 mg in volume not > 5 mL.
When evaluated for selected physicochemical properties, we found that caspofungin at both concentrations dissolves readily in solution of either water or 0.9% NaCl. Viscosity of both solutions measured close to that of water that readily formed aerosols on jet nebulization. However, caspofungin solutions were found to have acidic pH (pH 6.3), which required addition of 0.3N NaOH buffer for adjustment to physiologic range of pH 7.4. Solutions of extreme pH have been shown to affect airway tolerability by eliciting cough.23 In addition, we recommend that 0.9% NaCl be used as drug diluent for inhalation rather than sterile water in order to achieve concentrations of chloride ions and osmolalities within the range of tolerable limits of the airways.
Three commercial jet nebulizing systems were evaluated to determine the optimal delivery system in terms of output efficiency and particle size generated for the adjusted caspofungin solutions. The amount of drug aerosolized over time and the range of aerosol particle size generated have been shown to vary widely dependent on the device used.24 We found that the amount of drug output over time increases proportionally with increasing concentration for two systems (Envoy/Sidestream MS 2400 and Pulmo-Aide/Micromist) and twice the expected increase for the Proneb Ultra/Pari LC Star system. In addition, the fraction of particles generated in the RF varies by as much as 2.4-fold between devices and by 2-fold between concentrations of solution within device.
The ideal nebulizing system is one in which the highest percentage of drug aerosolized is delivered in particle size within the RF resulting in minimal drug wastage, and that drug delivery is completed in the least amount of time to promote patient compliance. When use of a disposable jet nebulizer is desired such as for drug administration in the hospital or clinical setting, we recommend that a caspofungin 10 mg/mL solution be used with the Pulmo-Aide compressor paired with the Micromist nebulizer. However, for in-home administration, we recommend the more concentrated drug solution (caspofungin, 30 mg/mL) be used with the reusable Pari-LC Star jet nebulizer coupled with the Proneb Ultra compressor to achieve the greatest efficiency in aerosol delivery. Aerosolization is complete in < 15 min for both systems.
We recognize several potential limitations to our in vitro evaluation of the physicochemical factors involved in generating caspofungin aerosols and characterization of the aerosol particle size and distribution. Several factors can potentially affect aerosol deposition in the lungs in vivo. First, the breathing pattern of the patient can affect aerosol deposition in the airways.14 Despite the generation of a high percentage of caspofungin aerosols in the RF for certain nebulizing systems tested, rapid and shallow breathing of the patient can enhance aerosol deposition in large airways by inertial impaction. Aerosols deposited in large airways can be readily exhaled out or cleared by mucociliary action and do not reach the target site which is the peripheral airways and alveoli in the lungs.17 In addition, humidity in the airways may also increase the particle size of hygroscopic droplets once they enter the respiratory tract, although this has not been demonstrated to be a significant determinant in therapeutic aerosol deposition.17 Finally, aerosol particle size and size distribution can be determined via different methods. Instruments such as cascade impactors and multistage liquid impingers determine mass size distribution directly, whereas light-scattering aerosol photometers and the time-of-flight spectrometer used in this work infer mass size distribution from individual particle measurements and can be subject to error if the sampled aerosol concentration is too high.2025 Therefore, we were careful to maintain experimental conditions that minimized such error sources. It should also be noted that the API Aerosizer measured droplet size distribution, and the drug content of the respirable droplet mass fraction was estimated assuming a uniform concentration of drug in all droplets. This is a reasonable assumption given the highly quasimonodisperse nature of the nebulizer aerosols.
| Conclusion |
|---|
|
|
|---|
| Footnotes |
|---|
This study was supported by a research grant from Merck Company.
Received for publication January 31, 2005. Accepted for publication May 22, 2005.