Chest ACCP Education Calendar
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     

Guest Access | Sign In via User Name/Password
This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Raviv, G.
Right arrow Articles by Millman, R. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Raviv, G.
Right arrow Articles by Millman, R. P.
(Chest. 2006;129:214-215.)
© 2006 American College of Chest Physicians

Is SNAP Technology Accurate in the Diagnosis of Obstructive Sleep Apnea?

Gil Raviv, PhD

SNAP Laboratories International, Wheeling, IL

Correspondence to: Gil Raviv, PhD, SNAP Laboratories International, LLC, 5210 Capitol Dr, Wheeling, IL 60090; e-mail: gil{at}snaplab.com

To the Editor:

Dr. Kehoe’s letter (April 2005)1 identified serious methodological shortcomings in the study by Liesching et al2 (March 2004) and shed significant doubt on the conclusions of the study. Dr. Millman’s rebuttal (April 2005)3 compelled my response.

First, Millman denied the existence of published literature on SNAP test reliability. In fact, Su et al4 in their study conducted at the University of Chicago, concluding the following: "The results ... demonstrate... good correlation between SNAP and polysomnography in quantifying RDI [respiratory disturbance index] with new reliable sensitivity, specificity, positive and negative predictive values... [thus]... SNAP is an excellent tool for the diagnosis of OSAS [obstructive sleep apnea syndrome]... ." The article demonstrated via receiver operating characteristic curves (Fig 3, 4 in the article by Su et al4) that a SNAP test accurately identified apnea severity. Su et al4 utilized a more powerful design performing both tests simultaneously. In contrast, Liesching et al2 have been soundly criticized for comparing data from the SNAP test and polysomnography findings that were collected, on average, 5 months apart.12 Given the stronger design of the study by Su et al,4 the startling variant conclusions offered by Liesching et al2 should be substantially discounted.

Second, Millman claimed that the initial continuous positive airway pressure derived from the clinically proven Miljeteig-Hoffstein method and reported by SNAP testing differed from the titration pressure that had been determined in his laboratory. This difference was never mentioned in his article; nor were data supporting his claim mentioned when the article was submitted for peer review. In contrast, the Miljeteig-Hoffstein formula has been well-validated.56

Finally, in his latest reply, Millman admitted systematically excluding patients who had been found to be nonapneic by the SNAP test. Why was this not fully disclosed in the article? Eliminating nonapneic patients as well as four patients with obviously severe disease (who excluded due to a split-night polysomnography study) weighted the sample heavily toward patients with mild apnea, introducing a substantial bias given the higher night-to-night variability in that group of patients. Omitting crucial details in his article pours cold water on Millman’s defensive statement "our article went through vigorous peer review to be accepted by CHEST."

References

  1. Kehoe, T (2005) SNAP technology and sleep apnea [letter]. Chest 127,1465-1466[Free Full Text]
  2. Liesching, FN, Carlisle, C, Marte, A, et al Evaluation of the accuracy of SNAP technology sleep sonography in detecting obstructive sleep apnea in adults compared to standard polysomnography. Chest 2004;125,886-889[Abstract/Free Full Text]
  3. Millman, RP Response to: SNAP technology and sleep apnea [letter]. Chest 2005;127,1466-1467
  4. Su, S, Baroody, FM, Kohrman, M, et al Comparison of polysomnography and a portable home sleep study in the diagnosis of obstructive sleep apnea syndrome. Otolaryngol Head Neck Surg 2004;131,844-850[CrossRef][ISI][Medline]
  5. Miljeteig, H, Hoffstein, V Determinants of continuous positive airway pressure level for treatment of obstructive sleep apnea. Am Rev Respir Dis 1993;147,1526-1530[ISI][Medline]
  6. Masa, JF, Jimenez, A, Duran, J, et al Alternative methods of titrating continuous positive airway pressure: a large multicenter study. Am J Respir Care Med 2004;170,1218-1224[Abstract/Free Full Text]

Richard P. Millman, MD, FCCP

Brown Medical School, Providence, RI

Correspondence to: Richard P. Millman, MD, FCCP, Rhode Island Hospital, APC 479A, Division of Pulmonary and Critical Care Medicine, 593 Eddy St, Providence, RI 02903-4923; e-mail: rmillman{at}lifespan.org

To the Editor:

Dr. Gil Raviv has faulted us for stating that our article1 was the first published article about SNAP technology. In fact, it was the first article about SNAP and came out prior to the publication of the University of Chicago study that appeared in Otolaryngology Head and Neck Surgery in 2004.2 We originally submitted our publication for consideration in CHEST on October 9, 2002, and the revision was accepted September 30, 2003. In addition, our article came out in early 2004, before the University of Chicago publication. We, therefore, had no knowledge about this study. At the time of our study, there were no peer-reviewed published articles about SNAP technology. In fact, Dr. Thomas Kehoe’s letter3 notes that, prior to the publication of the University of Chicago study, there were five separate validation studies performed on SNAP, but none of them were published. He even implied3 that there was a conspiracy to keep these studies from being published: "Previous attempts to publish these side-by-side blind studies have met with strong resistance by journals with review committees dominated by sleep specialists."

I have no objections to any type of type 3 recording device, as long as it has gone through rigorous peer review. As I mentioned in my previous letter to the editor,4 I feel there is a potential role for portable studies in select patients with a high pretest clinical suspicion for sleep apnea.

In regard to another comment by Dr. Raviv, he noted that we systemically excluded patients that were found to be nonapneic by SNAP testing. We did not exclude these patients on purpose. They simply were not referred to us. The primary care physicians who used SNAP technology were told by the SNAP sales force that a negative study was indeed negative. The physicians, therefore, did not refer patients with a negative study to us. This does not mean that the patients did not have sleep apnea. In fact, studies56 have shown that a negative sleep evaluation should be repeated, even if the initial evaluation was standard polysomnography, if there is a high suspicion for sleep apnea. Although there are deficiencies in our study, we had no other peer-reviewed data available to us at that time.

References

  1. Liesching, TN, Carlisle, C, Marte, A, et al Evaluation of the accuracy of SNAP technology sleep sonography in detecting obstructive sleep apnea in adults compared to standard polysomnography. Chest 2004;125,886-891
  2. Su, S, Baroody, FM, Kohrman, M, et al A comparison of polysomnography and a portable home sleep study in the diagnosis of obstructive sleep apnea syndrome. Otolaryngol Head Neck Surg 2004;131,844-850[CrossRef][ISI][Medline]
  3. Kehoe, TJ SNAP technology and sleep apnea [letter]. Chest 2005;127,1465-1466
  4. Millman, RP Response [letter]. Chest 2005;127,1466-1467
  5. Meyer, TJ, Eveloff, SE, Kline, LR, et al One negative polysomnogram does not exclude obstructive sleep apnea. Chest 1993;103,756-760[Abstract/Free Full Text]
  6. Stepnowsky, CJ, Orr, WC, Davidson, TM Nightly variability of sleep-disordered breathing measured over 3 nights. Otolaryngol Head Neck Surg 2004;131,837-843[CrossRef][ISI][Medline]




This Article
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Article Archive
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Raviv, G.
Right arrow Articles by Millman, R. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Raviv, G.
Right arrow Articles by Millman, R. P.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS